Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Corona is accompanied by

A

Violet visible discharge in darkness

B

Hissing sound

C

Vibration

D

All of above

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option D

All of above

Quick Summary:

Corona is an electrical discharge brought on by the ionization of a fluid such as air surrounding a conductor that is electrically charged. When the potential gradient exceeds the dielectric strength of air, the surrounding air breaks down, resulting in a luminous glow, audible hissing, and mechanical vibrations.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

Corona is an electrical discharge brought on by the ionization of a fluid such as air surrounding a conductor that is electrically charged. When the potential gradient exceeds the dielectric strength of air, the surrounding air breaks down, resulting in a luminous glow, audible hissing, and mechanical vibrations.

ЁЯФв Key Formulas

Vc=m0g0╬┤rlnтБб(Dr)V_c = m_0 g_0 \delta r \ln(\frac{D}{r})VcтАЛ=m0тАЛg0тАЛ╬┤rln(rDтАЛ) тАФ disruptive critical voltage equation

Pc=242╬┤(f+25)rD(VтИТVc)2├Ч10┬░тИТ5P_c = \frac{242}{\delta} (f+25) \sqrt{\frac{r}{D}} (V-V_c)^2 \times 10┬░{-5}PcтАЛ=╬┤242тАЛ(f+25)DrтАЛтАЛ(VтИТVcтАЛ)2├Ч10┬░тИТ5 тАФ power loss due to corona

тЪЩя╕П Working Principle

The phenomenon occurs due to the non-uniform electric field around circular conductors. When the operating voltage exceeds the disruptive critical voltage (VcV_cVcтАЛ), air molecules near the conductor surface ionize. This creates charged particles that accelerate, leading to further ionization (Townsend discharge) and the characteristic manifestations listed.

ЁЯУМ Key Points
  • тЦ╕

    Corona is more prevalent in AC systems than DC systems.

  • тЦ╕

    It causes power loss and can interfere with radio communication due to harmonic generation.

  • тЦ╕

    Rough and dirty conductors increase the likelihood of corona discharge.

  • тЦ╕

    The presence of ozone gas is a chemical side effect of corona.

тЬЕ Advantages
  • тЦ╕

    Acts as a natural lightning arrester for overhead lines by dissipating some energy

тЭМ Disadvantages / Limitations
  • тЦ╕

    Results in significant power loss

  • тЦ╕

    Causes electromagnetic interference (EMI) with communication lines

  • тЦ╕

    Leads to the formation of ozone gas, which is corrosive to the conductor material

ЁЯУД Additional Information
  • тЦ╕

    Visible discharge appears as a faint violet light.

  • тЦ╕

    Hissing sound is produced due to the oscillatory motion of air ions.

  • тЦ╕

    Vibration is caused by the electrostatic repulsion between the ionized air and the conductor surface.

ЁЯУК Diagram / Illustration
Corona EffectsConductorGlow, Hissing, Ozone, Vibration
тЬЕ

D is correct тАФ Corona discharge manifests physically through light emission, acoustic noise, and mechanical oscillations.

Core Concepts Used
Click any tag to open in AI Tutor
Dielectric Strength of Air Ionization Potential Potential Gradient
ЁЯТб EXAM TIP

Always remember that corona loss is directly proportional to (f+25)(f+25)(f+25), meaning higher frequency systems (like those in aircraft or high-frequency drives) suffer significantly more corona losses than standard 50Hz/60Hz grid power.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext