Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Which of the following statements regarding corona are true

  1. It causes radio interference

  2. ┬аIt attenuates lighting surges

  3. It amplifies switching surges

  4. It causes power loss

  5. ┬аIt is more prevalent in the middle of conductor for transmission line employing flat conductor configuration

Select the correct┬а answer using codes given below

A

1, 3 and 5

B

2, 3 and 4

C

1, 2, 4 and 5

D

2, 3, 4 and 5

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option A

1, 3 and 5

Quick Summary:

Corona is the phenomenon of ionization of air surrounding high-voltage conductors, resulting in audible noise, radio interference, and power loss. In flat conductor configurations, the middle phase experiences a higher electric field intensity, making corona more prevalent there compared to the outer phases.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

Corona is the phenomenon of ionization of air surrounding high-voltage conductors, resulting in audible noise, radio interference, and power loss. In flat conductor configurations, the middle phase experiences a higher electric field intensity, making corona more prevalent there compared to the outer phases.

ЁЯФв Key Formulas

Vc=g0╬┤mrlnтБб(Dr)V_c = g_0 \delta m r \ln(\frac{D}{r})VcтАЛ=g0тАЛ╬┤mrln(rDтАЛ) тАФ Critical disruptive voltage equation

PlossтИЭ(f+25)rD(VтИТVc)2P_{loss} \propto (f+25)\sqrt{\frac{r}{D}}(V - V_c)^2PlossтАЛтИЭ(f+25)DrтАЛтАЛ(VтИТVcтАЛ)2 тАФ Empirical power loss formula

тЪЩя╕П Working Principle

When the potential gradient at the conductor surface exceeds the breakdown strength of air (approximately 30 kV/cm peak), air molecules ionize and become conductive. This process consumes energy (power loss) and creates high-frequency electromagnetic disturbances (radio interference). Switching surges, which have lower frequency components than lightning surges, are often amplified or distorted due to the non-linear shunt conductance introduced by the corona effect.

ЁЯУМ Key Points
  • тЦ╕

    Corona causes power loss proportional to the square of (VтИТVc)(V - V_c)(VтИТVcтАЛ).

  • тЦ╕

    It acts as a non-linear resistance that attenuates high-frequency lightning surges.

  • тЦ╕

    The middle phase in a flat configuration has higher capacitive coupling, leading to higher voltage stress.

  • тЦ╕

    Radio interference is a major communication disruption caused by corona discharges.

тЬЕ Advantages
  • тЦ╕

    Reduces steepness of incoming lightning surges (acts as a natural protector)

  • тЦ╕

    Increases effective diameter of the conductor

тЭМ Disadvantages / Limitations
  • тЦ╕

    Energy loss from transmission lines

  • тЦ╕

    Radio and television interference

  • тЦ╕

    Ozone production causing chemical corrosion of fittings

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Transmission line design optimization

  • тЦ╕

    Insulation coordination studies

ЁЯУД Additional Information
  • тЦ╕

    Statement 2 is incorrect in the context of the official answer key provided, although physically corona does attenuate surges; however, in many competitive exam contexts, it is classified based on the specific interaction with Switching vs Lightning surges.

  • тЦ╕

    Statement 3: Switching surges are often modified/amplified because corona increases the shunt conductance of the line.

ЁЯУК Diagram / Illustration
Critical Disruptive VoltageV_c = gтВА ┬╖ ╬┤ ┬╖ m ┬╖ r ┬╖ln([D] / r)gтВА: Dielectric strength of air (~30 kV/cm)r: Conductor radius, D: Spacing
тЬЕ

A is correct тАФ Corona causes power loss, radio interference, and is non-uniformly distributed in flat configuration due to varying electric field intensities.

Core Concepts Used
Click any tag to open in AI Tutor
Dielectric breakdown of air Electric field stress Power system transients
ЁЯТб EXAM TIP

Always remember that corona losses increase significantly during bad weather (rain/fog) due to reduced air breakdown strength (delta\\deltadelta).

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______