Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Drying of winding should be done during____________

A

Periodic maintenance

B

Preventive maintenance

C

Breakdown maintenance

D

Routine maintenance

Correct Answer

Concept & PrincipleElectricalPower System
Option B

Preventive maintenance

Quick Summary: Drying of electrical machine windings is a standard preventive maintenance procedure performed to remove moisture absorbed by the insulation material. Moisture significantly lowers the insulation resistance (IR) and dielectric strength, which is corrected via drying to ensure the long-term reliability and safety of the equipment.

💡 Explanation

Drying of electrical machine windings is a standard preventive maintenance procedure performed to remove moisture absorbed by the insulation material. Moisture significantly lowers the insulation resistance (IR) and dielectric strength, which is corrected via drying to ensure the long-term reliability and safety of the equipment.

🔢 Key Formulas

Rins∝1MR_{ins} \propto \frac{1}{M}Rins​∝M1​ — Where MMM is the moisture content in the insulation

Q=mcΔTQ = mc\Delta TQ=mcΔT — Heat energy required for moisture removal

⚙️ Working Principle

Moisture ingress over time reduces the insulation resistance RinsR_{ins}Rins​ of windings. During preventive maintenance, external heat (via hot air blowers, induction heating, or circulating current) is applied to the winding to raise its temperature above the ambient dew point, causing water vapor to evaporate. The process is monitored by measuring the insulation resistance until it reaches a stable, safe threshold as per standards like IS 2026.

📌 Key Points
  • ▸

    Drying is essential if insulation resistance (IR) values drop below the recommended limits.

  • ▸

    Common methods include oven drying, short-circuit drying, and hot air circulation.

  • ▸

    Always perform a 'Polarization Index' (PI) test before and after drying to assess the condition.

  • ▸

    Preventive maintenance ensures drying is done before insulation failure occurs.

✅ Advantages
  • ▸

    Increases the operational lifespan of the winding insulation

  • ▸

    Prevents partial discharge and potential dielectric breakdown

❌ Disadvantages / Limitations
  • ▸

    Requires equipment downtime

  • ▸

    Needs controlled temperature monitoring to prevent thermal degradation of insulation

🛠️ Applications / Uses
  • ▸

    Large power transformers

  • ▸

    High voltage induction and synchronous motors

📄 Additional Information
  • ▸

    If the IR value is below 1 MΩ\OmegaΩ per kV, immediate drying is generally recommended.

  • ▸

    Breakdown maintenance is corrective, not proactive; waiting for a fault to dry a winding is hazardous.

📊 Diagram / Illustration
Insulation Resistance RecoveryMoisture Evaporation RateHeat Energy Input (Q)
Process: Drying effectively increases RinsR_{ins}Rins​
Outcome: Dielectric strength restoration
✅

B is correct — Drying of windings is a planned, proactive task performed during preventive maintenance to ensure moisture is removed before it leads to insulation failure.

Core Concepts Used
Click any tag to open in AI Tutor
Insulation Resistance Dielectric Strength Preventive Maintenance
💡 EXAM TIP

Always check the Polarization Index (PI) value: a PI ratio <1.25< 1.25<1.25 indicates the insulation is likely damp and requires a drying process.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)

Loading discussion...
PrevNext