Join 60,000+ competitive exam aspirants
For 11 kV transmission line, the capacitance per km will be about
0.01 F
0.1 F
0.01╬╝F
0.1╬╝F
0.01╬╝F
For overhead transmission lines, the shunt capacitance per unit length is typically in the order of 0.01╬╝F per kilometer. This value arises due to the potential difference between conductors (or between conductors and earth), which act as plates of a capacitor separated by air as a dielectric medium.
For overhead transmission lines, the shunt capacitance per unit length is typically in the order of 0.01╬╝F per kilometer. This value arises due to the potential difference between conductors (or between conductors and earth), which act as plates of a capacitor separated by air as a dielectric medium.
C=ln(D/r)2╧А╧╡0тАЛтАЛ тАФ Capacitance per unit length for a two-wire line
C=ln(D/reqтАЛ)2╧А╧╡0тАЛтАЛ тАФ Capacitance for a three-phase transposed line
The capacitance of a transmission line is determined by the physical geometry of the conductors (radius and spacing) and the permittivity of the surrounding medium (air, where ╧╡rтАЛтЙИ1). Using the formula for a two-wire line, C=ln(D/r)╧А╧╡тАЛ, the logarithmic dependence results in values typically ranging from 0.008 to 0.015╬╝F/km for standard overhead configurations.
Capacitance is a shunt parameter that affects the charging current of the line.
The value depends primarily on the conductor spacing (D) and radius (r).
Line capacitance increases the voltage profile at the receiving end due to the Ferranti effect under light loads.
For short lines, shunt capacitance is often neglected, but it is critical for long and medium-length transmission lines.
Useful for voltage regulation studies.
Essential for modeling long lines using the PI or T network models.
Causes constant charging current flow even if the line is open-circuited.
Contributes to the Ferranti effect, leading to high receiving-end voltages.
Power system steady-state analysis.
Calculation of transmission line charging MVAR.
The value 0.01 ╬╝F/km is a standard empirical reference for typical 11 kV to 132 kV overhead lines.
Option B (0.1 ╬╝F) is significantly higher than the physical capacitance of standard overhead lines and is more representative of underground cables, which have much higher capacitance due to closer proximity and insulating materials.
C is correct тАФ The capacitance per km for an overhead transmission line is typically approximately 0.01 ╬╝F/km.
Always remember that underground cables have much higher capacitance (up to 0.2-0.4 ╬╝F/km) compared to overhead lines due to the small distance between the conductor and the metallic sheath.