Join 60,000+ competitive exam aspirants
Transmission of power by AC cables is impossible beyond
35 to 45 km
500 km
300 km
1000 km
35 to 45 km
Transmission of power by AC cables is effectively limited to 35 to 45 km due to the high shunt capacitive current associated with underground cables. As the length increases, the charging current consumes a significant portion of the cable's current-carrying capacity, leaving little room for the actual load current.
Transmission of power by AC cables is effectively limited to 35 to 45 km due to the high shunt capacitive current associated with underground cables. As the length increases, the charging current consumes a significant portion of the cable's current-carrying capacity, leaving little room for the actual load current.
ICтАЛ=VтЛЕ2╧АfC тАФ Charging current of a transmission cable
C=ln(D/d)2╧А╧╡0тАЛ╧╡rтАЛlтАЛ тАФ Capacitance of a single-core cable
Underground cables have a much smaller spacing between conductors and a dielectric with a higher permittivity compared to overhead lines, resulting in very high shunt capacitance (C). In AC systems, this capacitance draws a charging current ICтАЛ=VтЛЕ╧ЙтЛЕC. For long cable runs, ICтАЛ becomes so large that it accounts for the entire thermal capacity of the cable, effectively preventing the transmission of useful power to the load.
AC cables exhibit high shunt capacitance per unit length.
The charging current increases linearly with the length of the cable.
Beyond critical length, the cable carries only charging current and no load current.
High-Voltage Direct Current (HVDC) is preferred for long-distance underground transmission as it eliminates the capacitive charging current issue.
Elimination of electromagnetic interference
Suitable for urban and densely populated areas
High cost compared to overhead transmission lines
Difficulty in locating and repairing faults
Limited transmission distance for AC systems
Underground distribution in urban centers
Submarine power transmission across short distances
The limit of 35-45 km is a standard rule of thumb for medium voltage AC cables.
Options B, C, and D represent distances far exceeding the dielectric and thermal limits for AC cable stability.
A is correct тАФ AC cables are restricted by excessive capacitive charging current that limits effective power transfer to distances typically between 35 and 45 km.
If you encounter a question about long-distance underground transmission (hundreds of km), remember that HVDC is the only viable solution because it does not suffer from capacitive charging currents.