Join 60,000+ competitive exam aspirants
For a specific open-circuit voltage of a DC generator, the short-circuit electric current will be maximum when it is
shunt connected
differentially compounded
cumulatively compounded
separately excited
cumulatively compounded
In a cumulatively compounded DC generator, the series field flux aids the shunt field flux, resulting in a higher total flux for a given load current compared to other types. During short-circuit conditions, the cumulative interaction of these windings sustains a higher magnetic field, leading to a maximum short-circuit current.
In a cumulatively compounded DC generator, the series field flux aids the shunt field flux, resulting in a higher total flux for a given load current compared to other types. During short-circuit conditions, the cumulative interaction of these windings sustains a higher magnetic field, leading to a maximum short-circuit current.
╬жtotalтАЛ=╬жshтАЛ+╬жseтАЛ тАФ Total flux in cumulative compound generator
EgтАЛ=60AP╬жZNтАЛ тАФ Induced EMF formula showing dependency on total flux
When a short circuit occurs, the voltage across the machine drops, but in a cumulatively compounded machine, the series field winding carries the short-circuit current. Because the series field flux acts in the same direction as the shunt field flux, the total flux per pole increases or remains significant, inducing a higher electromotive force and thus a larger short-circuit current than a differentially compounded or separately excited generator.
Cumulative compounding leads to a rising external characteristic curve.
Differentially compounded generators exhibit a sharply drooping characteristic due to flux opposition.
Short-circuit current depends directly on the excitation strength at low terminal voltage.
Provides compensating voltage drop for load variations
Maintains higher terminal voltage under load
Vulnerable to high currents during fault conditions
Requires more complex winding construction
Long-distance power transmission
Industrial drives requiring stable voltage under varying load
| Feature | Cumulative | Differential |
|---|---|---|
Flux Interaction | Additive (╬жshтАЛ+╬жseтАЛ) | Subtractive (╬жshтАЛтИТ╬жseтАЛ) |
Differentially compounded generators are often used in arc welding where a steep drooping characteristic is required to limit short-circuit current.
Option B is incorrect because differential flux reduces the resultant flux to a near-zero value during short circuits, effectively limiting the fault current.
C is correct тАФ Cumulative compounding increases the total magnetic flux during short circuit, which in turn induces a larger current compared to other excitation configurations.
Always remember that in electrical machines, the 'Cumulative' prefix implies physical addition of fields, which always results in higher flux and higher torque/current potential compared to 'Differential' types.