Which of the following DC generators has rising V-I characteristics?
Shunt
Series
Compound
None of the above
Series
A DC series generator exhibits rising V-I characteristics because the load current flows directly through the series field winding, causing the flux to increase with the load. As load current increases, the terminal voltage initially rises due to the increase in generated EMF, which overcomes the combined ohmic voltage drops until the magnetic saturation point is reached.
A DC series generator exhibits rising V-I characteristics because the load current flows directly through the series field winding, causing the flux to increase with the load. As load current increases, the terminal voltage initially rises due to the increase in generated EMF, which overcomes the combined ohmic voltage drops until the magnetic saturation point is reached.
V=EgтАЛтИТILтАЛ(RaтАЛ+RseтАЛ) тАФ Terminal voltage equation for a DC series generator
EgтАЛ=60A╬жZNPтАЛ тАФ Generated EMF proportional to flux ╬ж
The terminal voltage V=EgтАЛтИТIaтАЛ(RaтАЛ+RseтАЛ). In a series generator, IaтАЛ=IseтАЛ=ILтАЛ. As load current ILтАЛ increases, the field flux ╬ж increases proportionally (below saturation), leading to a rapid increase in induced EMF EgтАЛ according to EgтАЛ=60AP╬жZNтАЛ. The rising rate of EgтАЛ initially outpaces the I(RaтАЛ+RseтАЛ) drop, resulting in an upward-sloping characteristic curve.
Series generator terminal voltage is directly dependent on the load current.
The V-I curve starts from near zero and rises until saturation occurs.
It is unsuitable for constant voltage applications without auxiliary controls.
The series field winding is designed with a few turns of thick wire to handle high load current.
High starting voltage potential
Simple construction for specific load requirements
Terminal voltage varies significantly with load changes
Not capable of generating voltage at no-load condition
Used as a booster in DC distribution systems
Used in series arc lighting and constant current power supplies
Shunt generators exhibit a drooping V-I characteristic due to armature reaction and ohmic drop.
Compound generators are designed to be flat-compounded, under-compounded, or over-compounded based on field winding configuration.
B is correct тАФ The DC series generator shows a rising terminal voltage with an increase in load current due to the proportional increase in field flux.
Always remember that in series machines, the load current is the excitation current; therefore, load variations directly dictate the machine's magnetic state.