For the transmission of the same amount of power with same efficiency over same distance with the same consumer voltage in comparison to a DC two wire distributor,┬а three wire distributor needs
31.25 % copper
33.3% copper
66.6% copper
5 times copper
31.25 % copper
A DC three-wire system utilizes two outer wires and a neutral wire. Compared to a two-wire DC system, the voltage between outer wires is doubled, which allows for a reduction in cross-sectional area and weight of the conductors while maintaining the same power transfer, distance, and efficiency.
A DC three-wire system utilizes two outer wires and a neutral wire. Compared to a two-wire DC system, the voltage between outer wires is doubled, which allows for a reduction in cross-sectional area and weight of the conductors while maintaining the same power transfer, distance, and efficiency.
W3тИТwireтАЛ=165тАЛW2тИТwireтАЛ тАФ Relative weight of copper for 3-wire DC system
P=VI тАФ Power relationship assuming constant voltage
In a three-wire DC system, the voltage between outers is 2V, whereas in a two-wire system it is V. Since power P=VI, doubling the voltage for the same power allows the current I to be halved. Furthermore, the neutral wire typically carries little current, reducing the total copper requirement to 31.25% of the two-wire system weight.
The DC 3-wire system effectively operates at twice the voltage of a 2-wire system for the same load.
Copper weight savings are achieved because I2R losses are minimized by higher voltage transmission.
The neutral wire size is usually kept as half the size of the outer wires, leading to the 31.25% ratio.
Higher efficiency due to reduced transmission current
Availability of two different voltage levels (V and 2V)
Increased complexity in maintenance and switching
Requires a balanced load for optimal neutral performance
Historical DC distribution networks
Industrial specific-purpose DC traction systems
| Feature | Reference | Comparison |
|---|---|---|
System Type | DC 2-wire | DC 3-wire |
Copper Weight | 100% | 31.25% |
This calculation assumes the neutral wire has a cross-section half that of the outer wires.
Option B (33.3%) is often mistaken for a simple fraction error, but 31.25% is the precise mathematical result based on copper volume calculations.
A is correct тАФ The DC three-wire system requires only 31.25% of the copper weight compared to a two-wire system for identical transmission constraints.
In competitive exams, always remember that for 3-phase AC systems compared to DC, the ratios change; differentiate clearly between DC and AC system copper comparisons.