Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Grounding is done generally at

A

Receiving end

B

Supply end

C

Either at receiving end or at a supply end

D

None of above

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option B

Supply end

Quick Summary:

Neutral grounding refers to the intentional connection of the system neutral to the earth at the supply end (e.g., at the transformer or generator star point). This practice fixes the neutral potential to ground and provides a defined return path for zero-sequence currents during fault conditions.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

Neutral grounding refers to the intentional connection of the system neutral to the earth at the supply end (e.g., at the transformer or generator star point). This practice fixes the neutral potential to ground and provides a defined return path for zero-sequence currents during fault conditions.

ЁЯФв Key Formulas

Vphase=Vline3V_{phase} = \frac{V_{line}}{\sqrt{3}}VphaseтАЛ=3тАЛVlineтАЛтАЛ тАФ Relation between phase and line voltage in star system

If=VphZnI_f = \frac{V_{ph}}{Z_n}IfтАЛ=ZnтАЛVphтАЛтАЛ тАФ Fault current magnitude calculation involving grounding impedance ZnZ_nZnтАЛ

тЪЩя╕П Working Principle

In a star-connected system, the neutral point is the common junction. By connecting this point to the ground, the system voltage relative to earth is stabilized. During a line-to-ground fault, the grounding path allows fault current to flow, which can be detected by protective relays to isolate the faulty section.

ЁЯУМ Key Points
  • тЦ╕

    Grounding stabilizes the voltage levels relative to the ground.

  • тЦ╕

    It prevents the creation of excessive potential differences between phases and earth.

  • тЦ╕

    It facilitates the operation of protective equipment by providing a path for fault currents.

  • тЦ╕

    Grounding is essential for equipment insulation coordination.

тЬЕ Advantages
  • тЦ╕

    Protection against arcing grounds

  • тЦ╕

    Improved safety for personnel and equipment

  • тЦ╕

    Simplified earth fault detection

тЭМ Disadvantages / Limitations
  • тЦ╕

    High magnitude of fault current compared to ungrounded systems

  • тЦ╕

    Increased interference with neighboring communication lines

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Power transmission systems

  • тЦ╕

    Distribution transformers

  • тЦ╕

    Industrial motor drives

ЁЯУД Additional Information
  • тЦ╕

    In industrial and utility systems, the transformer or generator star point is the designated 'supply end' for grounding.

  • тЦ╕

    Option A is incorrect because the receiving end equipment usually relies on local equipment earthing rather than system neutral grounding.

ЁЯУК Diagram / Illustration
Neutral Grounding SystemNeutral PointEarth
тЬЕ

B is correct тАФ Neutral grounding is performed at the supply end (generator or transformer star point) to provide a firm reference for system potential.

Core Concepts Used
Click any tag to open in AI Tutor
Neutral Grounding System Earthing Fault Protection
ЁЯТб EXAM TIP

Always distinguish between 'System Grounding' (neutral point to ground) and 'Equipment Grounding' (metal chassis to ground) as they serve different safety purposes.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______