Identify starter type from the diagram given below.
Automatic Back EMF DC Shunt Motor Starter
Automatic Time Delay DC Shunt Motor Starter
Manual Time Delay DC Shunt Motor Starter
Automatic DC Series Motor Starter
Automatic Time Delay DC Shunt Motor Starter
The diagram represents an Automatic Time Delay DC Shunt Motor Starter, which uses timing relays (timers or time-delay contactors) to short-circuit sections of starting resistance in predetermined time intervals regardless of armature current or back EMF. When the start button is pressed, the main contactor energizes, applying line voltage across the field and armature through external starting resistors; subsequent time-delay relays progressively close contactors to cut out starting resistance step-by-step as time elapses.
The diagram represents an Automatic Time Delay DC Shunt Motor Starter, which uses timing relays (timers or time-delay contactors) to short-circuit sections of starting resistance in predetermined time intervals regardless of armature current or back EMF. When the start button is pressed, the main contactor energizes, applying line voltage across the field and armature through external starting resistors; subsequent time-delay relays progressively close contactors to cut out starting resistance step-by-step as time elapses.
IaтАЛ=RaтАЛ+RextтАЛVтИТEbтАЛтАЛ тАФ Armature current during starting process
EbтАЛ=60A╬жZNPтАЛ тАФ Back EMF generated by the DC motor armature
During motor startup, the absence of back EMF causes high inrush current given by IaтАЛ=RaтАЛ+RextтАЛVтИТEbтАЛтАЛ. Upon pressing the start button, the main contactor coil M energizes, starting the motor with all starting resistors in series with the armature. Simultaneously, time-delay relays (e.g., 1TD, 2TD) begin timing sequence; after preset delay intervals, they sequentially energize accelerating contactors (1A, 2A, etc.) to short-circuit resistance steps until the motor reaches full speed.
Operates strictly based on predetermined time intervals using time-delay relays (TD).
Independent of motor speed, back EMF, or armature current conditions during acceleration.
Ensures smooth acceleration and prevents motor from operating continuously on starting resistors.
Simple control circuitry design and predictable acceleration time.
Protects external starting resistors from overheating due to prolonged low-speed running.
Does not adapt to changing load inertia or heavy starting load conditions.
May cause high peak currents if load condition delays actual speed buildup.
Constant load DC shunt and compound motor drives.
Industrial automation drives requiring fixed-time acceleration sequences.
Option A (Automatic Back EMFStarter) relies on sensing armature voltage (EbтАЛ) build-up to energize contactors rather than time relays.
Option C is incorrect because automatic starters use electromagnetic contactors and control circuits, not manual handles.
Option D (DC Series Motor Starter) requires field winding in series with armature, whereas shunt starters keep field directly connected across supply lines.
B is correct тАФ The presence of time-delay control relays (timers) that bypass starting resistors at fixed time intervals categorizes this as an Automatic Time Delay DC Shunt Motor Starter.
Remember: Definite-time (time-delay) starters use timers, back-EMF starters use voltage-sensing relays, and current-limit starters use current-sensing relays in the armature circuit.