If a synchronous machine is overexcited, it takes lagging VAR from the system when it is operated as a
Synchronous motor
Synchronous generator
Synchronous motor as well as generator
None of the above
None of the above
An overexcited synchronous machine acts as a source of reactive power (VAR). When operated as a motor, an overexcited machine delivers leading VAR to the system (acting like a capacitor), and when operated as a generator, it delivers lagging VAR to the system.
An overexcited synchronous machine acts as a source of reactive power (VAR). When operated as a motor, an overexcited machine delivers leading VAR to the system (acting like a capacitor), and when operated as a generator, it delivers lagging VAR to the system.
Q=XsтАЛVтАЛ(EbтАЛcos╬┤тИТV) тАФ Reactive power equation for synchronous machine
P=XsтАЛVEbтАЛтАЛsin╬┤ тАФ Active power equation
The reactive power behavior depends on the excitation level. An overexcited machine (EbтАЛ>V) generates reactive power (VAR). A synchronous motor takes leading current when overexcited (supplying VAR to the bus), while a synchronous generator delivers lagging current when overexcited (supplying lagging VAR to the load).
Under-excited synchronous machine takes lagging VAR (acts as an inductor).
Overexcited synchronous machine delivers lagging VAR (acts as a capacitor).
A synchronous condenser is an overexcited synchronous motor used for power factor correction.
Ability to control power factor.
Voltage regulation improvement.
Requires DC excitation source.
Higher maintenance compared to static capacitors.
Power factor correction in industrial plants.
Voltage support in transmission systems.
The question asks when the machine 'takes' lagging VAR. An overexcited machine always 'delivers' reactive power (whether it is lagging or leading depends on whether it is a motor or generator). Therefore, it never 'takes' lagging VAR when overexcited.
If the machine were under-excited, it would consume lagging VAR.
D is correct тАФ An overexcited synchronous machine always acts as a source of reactive power (delivering VAR), hence it never takes lagging VAR from the system.
Remember: Over-excitation always means the machine acts as a source of reactive power; under-excitation means it acts as a sink.