If the load on an RCC lintel due to the wall above it is in the form of a triangular portion, then the angle subtended by a triangle at either end of the lintel shall be:
60 degrees each
30 degrees each
50 degrees each
40 degrees each
60 degrees each
In structural masonry design, the load transferred to a lintel from the masonry above is traditionally assumed to follow an arching action. For calculation purposes, this load is simplified as a triangular distribution where the base is equal to the span of the lintel and the base angles are taken as 60┬░ each.
IS 1905:1987 (Code of practice for structural use of unreinforced masonry)
In structural masonry design, the load transferred to a lintel from the masonry above is traditionally assumed to follow an arching action. For calculation purposes, this load is simplified as a triangular distribution where the base is equal to the span of the lintel and the base angles are taken as 60┬░ each.
Load┬аArea=21тАЛ├ЧSpan├ЧHeight┬аof┬аTriangle
Height┬аof┬аTriangle=2SpanтАЛ├Чtan(60┬░)
The principle relies on the formation of a 'corbel' or 'arch' action in the brickwork, which is considered to support the masonry above a triangular area. This assumption restricts the load to a triangle with sides at 60┬░ to the horizontal, effectively ignoring the masonry weight outside this triangle for the structural design of the lintel.
The assumed triangular load ensures a conservative estimate for lintel design.
This method assumes the masonry has sufficient bond strength to form a compressive arch.
The base of the triangle is taken as the span of the opening.
If the height of the wall is less than the height of the triangle, the load is taken as the total weight of the wall.
Simplifies complex arching action into static load analysis
Provides a safe and conservative design approach for lintels
Does not account for actual arching variations based on mortar type
Neglects the contribution of friction between masonry units
Design of reinforced concrete (RCC) lintels
Design of steel beams used as lintels in masonry walls
If the wall is low, the triangular assumption is replaced by the actual weight of the wall.
The 60┬░ assumption is a standard empirical simplification used to ensure the lintel can carry the triangular wedge of the masonry.
A is correct тАФ The standard structural assumption for the triangular load distribution on a lintel involves a triangle with base angles of 60┬░.
Always verify if the height of the wall above the lintel is sufficient to form the full triangle; if the wall height is less than 2SpanтАЛ├Ч3тАЛ, use the actual wall weight instead.