Join 60,000+ competitive exam aspirants
In a 12 pole triplex lap wound DC armature, each conductor can carry a current of 100 A. The rated current of this armature is
600 A
1200 A
2400 A
3600 A
3600 A
In a lap-wound DC machine, the number of parallel paths (A) is equal to the product of the number of poles (P) and the multiplicity/degree of lap winding (m). For a triplex lap winding, m=3, so the total number of parallel paths is A=m├ЧP=3├Ч12=36.
In a lap-wound DC machine, the number of parallel paths (A) is equal to the product of the number of poles (P) and the multiplicity/degree of lap winding (m). For a triplex lap winding, m=3, so the total number of parallel paths is A=m├ЧP=3├Ч12=36.
A=m├ЧP тАФ Total parallel paths for lap winding
IaтАЛ=A├ЧIcтАЛ тАФ Total armature current calculation
The total rated current of the armature is the product of the current per conductor (IcтАЛ) and the total number of parallel paths (A). Since the conductors are connected in parallel to divide the total load current, the total capacity is IaтАЛ=A├ЧIcтАЛ. With A=36 and IcтАЛ=100┬аA, the total armature current is 36├Ч100=3600┬аA.
For simplex lap winding, m=1, so A=P.
For duplex lap winding, m=2, so A=2P.
For triplex lap winding, m=3, so A=3P.
Parallel paths provide higher current carrying capacity compared to wave windings.
High current capacity
Low voltage rating suitability
Requires large number of brushes
Not suitable for high voltage applications
Electroplating units
High current DC power supplies
The term 'triplex' indicates a multiplicity of m=3.
Option A (600 A) would be the answer for a simplex lap winding with only 6 poles.
Option B (1200 A) would be the answer for a simplex lap winding with 12 poles.
D is correct тАФ The total armature current is the product of the number of parallel paths (A=36) and the current per conductor (100┬аA), resulting in 3600┬аA.
Always identify the winding type first; remember that wave windings have only 2 parallel paths regardless of the number of poles.