Join 60,000+ competitive exam aspirants
Resistance commutation is used generally in case of
DC machines above 10 kW
DC machines bellow 5 kW
fractional kW DC machines
none of the above
fractional kW DC machines
Resistance commutation involves adding high-resistance carbon brushes to the commutator to force current reversal through external resistance rather than relying solely on induced EMF. This method is primarily used in fractional kW (small-sized) DC machines where high brush contact resistance significantly influences the reversal process.
Resistance commutation involves adding high-resistance carbon brushes to the commutator to force current reversal through external resistance rather than relying solely on induced EMF. This method is primarily used in fractional kW (small-sized) DC machines where high brush contact resistance significantly influences the reversal process.
IbrushтАЛ=RbrushтАЛVcontactтАЛтАЛ тАФ Current through the contact point
TcтАЛ=RcтАЛLcтАЛтАЛ тАФ Time constant of the commutating coil
In small DC machines, the short-circuited coil has low inductance, making it difficult to achieve sparkless commutation via induced voltage alone. By using high-resistance carbon brushes, the contact resistance creates a parallel path that forces the current I to decay and reverse polarity more rapidly. The current IbтАЛ through the contact follows the relation IbтАЛ=RbтАЛVcтАЛтАЛ, where RbтАЛ is high, effectively shortening the duration of the spark.
Used when commutating EMF is small due to low coil inductance.
Utilizes carbon brushes which have a negative temperature coefficient of resistance.
Effective for machines with small current ratings.
Helps in achieving sparkless commutation by increasing the circuit resistance.
Simple construction without requiring extra windings
Carbon brushes have a natural lubricating effect
Cost-effective for small motors
Higher power loss due to brush contact resistance
Not suitable for large DC machines with high current
Brush wear can be accelerated at high currents
Fractional horsepower universal motors
Small DC servomotors
Domestic appliance motors
In larger machines, interpol (commutating poles) are used instead of resistance commutation because brush losses become prohibitive.
Option B (below 5 kW) is a less precise category than fractional kW machines; 'fractional kW' specifically defines the design philosophy for resistance-dependent commutation.
C is correct тАФ Resistance commutation is specifically employed in fractional kW DC machines where low inductance allows high-resistance brushes to facilitate current reversal.
Always remember that resistance commutation works by increasing the resistance of the short-circuited coil path, whereas interpoles work by neutralizing the reactance voltage.