Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalBasic Electrical
PrevNext

In a cable immediately above metallic sheath ___________________ is provided.

A

earthing connection

B

bedding

C

armouring

D

none of above

Correct Answer

Concept & PrincipleElectricalBasic Electrical
Option B

bedding

Quick Summary: In an underground cable construction, the bedding layer is placed directly over the metallic sheath. Its primary purpose is to protect the metallic sheath from corrosion and from mechanical injury due to the pressure of the armouring.

💡 Explanation

In an underground cable construction, the bedding layer is placed directly over the metallic sheath. Its primary purpose is to protect the metallic sheath from corrosion and from mechanical injury due to the pressure of the armouring.

🔢 Key Formulas

Tmech∝FarmouringT_{mech} \propto F_{armouring}Tmech​∝Farmouring​ — Indicates that armouring provides mechanical protection, necessitating a buffer (bedding) to protect the sheath underneath.

⚙️ Working Principle

The metallic sheath (usually lead) is soft and vulnerable. When steel tape or wire armouring is applied for mechanical strength, the rough surface and high pressure of the armouring can damage or puncture the sheath. Bedding, typically composed of fibrous materials like jute or hessian, provides a cushioning effect and acts as a buffer layer to ensure longevity.

📌 Key Points
  • ▸

    Metallic sheath protects the insulation from moisture and chemicals.

  • ▸

    Bedding consists of fibrous materials such as jute or hessian impregnated with a preservative compound.

  • ▸

    Armouring protects the cable from mechanical damage (sharp objects, soil stress).

  • ▸

    Serving is the final outer layer protecting the armouring from atmospheric corrosion.

✅ Advantages
  • ▸

    Prevents electrolytic corrosion of the metallic sheath.

  • ▸

    Acts as a protective cushion against mechanical stress from armouring.

❌ Disadvantages / Limitations
  • ▸

    Increases the overall diameter and weight of the cable.

  • ▸

    Jute-based bedding is susceptible to rot if the outer serving is damaged.

🛠️ Applications / Uses
  • ▸

    High voltage underground power cables.

  • ▸

    Submarine cable construction where structural integrity is vital.

📄 Additional Information
  • ▸

    The metallic sheath is typically made of lead or aluminium.

  • ▸

    The sequence of layers from core to surface is: Conductor, Insulation, Metallic Sheath, Bedding, Armouring, Serving.

  • ▸

    Option A is incorrect because earthing is a safety feature applied externally; Option C is the layer applied above the bedding.

📊 Diagram / Illustration
Cable Cross-Section Layers1. Conductor & Insulation2. Metallic Sheath (Lead)3. Bedding (Jute/Hessian)4. Armouring (Steel)5. Serving (Outer Protection)
✅

B is correct — Bedding is the layer provided immediately above the metallic sheath to protect it from mechanical injury caused by the armouring.

Core Concepts Used
Click any tag to open in AI Tutor
Cable Construction Mechanical Protection Corrosion Prevention
💡 EXAM TIP

Always remember the order of cable layers (Core-Insulation-Sheath-Bedding-Armouring-Serving) using the mnemonic: CIS-BAS.

Related Questions

ElectricalBasic Electrical
Batteries are charged by
ElectricalBasic Electrical
48 ampere-hour capacity would deliver a current of
ElectricalBasic Electrical
The lead-acid cell should never be discharged beyond
ElectricalBasic Electrical
In a lead-acid cell, lead is called as
ElectricalBasic Electrical
Undercharging of chemical batteries

Discussion (0)

Loading discussion...
PrevNext