Join 60,000+ competitive exam aspirants
In a medium or high head hydro-electric power station, a surge tank is provided to
Reduce the length of the penstock pipes
Augment water at the forebay
Control the pressure variations in the penstock pipes due to sudden load changes
Control the water flow through the turbine
Control the pressure variations in the penstock pipes due to sudden load changes
A surge tank is an auxiliary reservoir located near the powerhouse in hydro-electric plants to act as a buffer for the water column. It protects the penstock from high-pressure surges, known as water hammer, caused by sudden fluctuations in turbine load and the resulting changes in flow rate.
A surge tank is an auxiliary reservoir located near the powerhouse in hydro-electric plants to act as a buffer for the water column. It protects the penstock from high-pressure surges, known as water hammer, caused by sudden fluctuations in turbine load and the resulting changes in flow rate.
hwhтАЛ=gaтЛЕvтАЛ тАФ calculation of water hammer head where a is wave velocity, v is flow velocity, and g is gravity.
P=╧БgQH╬╖ тАФ power output of the hydro-electric plant.
When a turbine load decreases, the governor closes the gates, causing a sudden deceleration of the moving water column. This inertia creates a high-pressure wave (water hammer). The surge tank provides an open space for the water to rise, absorbing the kinetic energy and dissipating the pressure rise. Conversely, during sudden load increases, the surge tank supplies additional water to the turbine, preventing negative pressure and cavitation.
Surge tanks effectively convert water hammer pressure energy into potential energy.
They are mandatory for medium and high-head plants where penstocks are long.
They improve the stability of the governing system by providing a short-term supply buffer.
Mitigates destructive water hammer effects.
Enhances governing stability during load transients.
Prevents cavitation and penstock damage.
Increases initial construction cost.
Requires significant structural design effort.
Adds to the complexity of the hydro-power infrastructure.
High-head hydro-electric power plants.
Long pipeline systems involving high inertia water columns.
Options A is incorrect as surge tanks do not shorten pipes; they actually increase site footprint.
Option B is incorrect because forebay augmentation is not the primary function of a surge tank.
Option D is incorrect because the turbine speed governor controls flow, not the surge tank.
C is correct тАФ A surge tank is specifically designed to act as a pressure reservoir that damps pressure surges in the penstock caused by sudden variations in turbine load.
Always remember that the 'Surge Tank' is fundamentally a pressure-relief device, whereas the 'Governor' is a flow-regulation device. They work together to maintain system equilibrium.