In a steam power plant heat from the flue gases is recovered in
condenser
chimney
Economizer and air preheater
super heater
Economizer and air preheater
In a steam power plant, heat recovery units are used to extract thermal energy from hot flue gases before they exit through the chimney. Specifically, the economizer preheats the boiler feed water, and the air preheater warms the combustion air, both of which significantly increase the overall plant thermal efficiency.
In a steam power plant, heat recovery units are used to extract thermal energy from hot flue gases before they exit through the chimney. Specifically, the economizer preheats the boiler feed water, and the air preheater warms the combustion air, both of which significantly increase the overall plant thermal efficiency.
╬╖overallтАЛ=QinтАЛWnetтАЛтАЛ тАФ represents the thermal efficiency of the power plant
╬ФQ=mcpтАЛ╬ФT тАФ heat recovered by the feed water or air
The economizer consists of a coil of tubes placed in the path of flue gases, allowing cold feed water to absorb waste heat, thus reducing the temperature difference in the boiler. The air preheater functions similarly by utilizing the remaining low-grade heat in the flue gases to heat the incoming forced draft air, which improves the combustion process and reduces fuel consumption.
Economizers reduce the fuel consumption by 5-10% in large thermal power plants.
Air preheaters improve combustion stability and allow the use of lower-grade coal.
Flue gas temperature at the chimney exit must be kept above the dew point to prevent corrosion.
Recovery of waste heat reduces the carbon footprint per MWh generated.
Increased overall thermal efficiency
Reduced fuel consumption
Improved boiler combustion performance
Increased capital cost of installation
Increased maintenance complexity due to tube fouling
Added pressure drop in flue gas path
Pulverized fuel thermal power plants
Industrial steam boilers
Combined heat and power (CHP) systems
Economizer and air preheater are essential components in the 'back-end' of the boiler configuration.
Option A (Condenser) is for rejecting latent heat to a cooling medium.
Option B (Chimney) is the structural outlet for exhaust gases, not a heat recovery device.
Option D (Superheater) adds sensible and latent heat to steam inside the boiler, not from exhaust flue gases.
C is correct тАФ Economizer and air preheater are the primary components designed to recover waste thermal energy from flue gases.
Always remember that the Economizer heats the water side (feed water) while the Air Preheater heats the air side (combustion air); both are critical for high-efficiency plant operation.