Join 60,000+ competitive exam aspirants
Economizer in a steam power plant
Improves the boiler efficiency by 10 - 12%
Saves fuel consumption by 5 - 15%
Becomes a necessity for pressure exceeding 70 kg/cm2
All of above
All of above
An economizer is a heat exchanger device installed in the flue gas path of a steam power plant to extract residual heat from exhaust gases. It preheats the boiler feed water using these gases, thereby reducing the fuel required to convert the water into steam, which directly enhances the overall plant thermal efficiency.
An economizer is a heat exchanger device installed in the flue gas path of a steam power plant to extract residual heat from exhaust gases. It preheats the boiler feed water using these gases, thereby reducing the fuel required to convert the water into steam, which directly enhances the overall plant thermal efficiency.
QsavedтАЛ=m╦ЩwтАЛcpтАЛ(ToutтАЛтИТTinтАЛ) тАФ Heat saved by the economizer
╬╖boilerтАЛ=m╦ЩfтАЛтЛЕCVm╦ЩsтАЛ(hsтАЛтИТhfтАЛ)тАЛ тАФ Boiler efficiency formula
The economizer works on the principle of waste heat recovery. By placing the unit in the flue gas path, the hot exhaust gases (which would otherwise be wasted) transfer energy to the relatively cooler feed water entering the boiler. This preheating process reduces the temperature gradient the boiler must overcome, resulting in lower fuel consumption and preventing thermal shock to boiler components.
Economizers recover waste heat from flue gases to preheat boiler feed water.
Fuel savings typically range between 5% and 15% depending on plant design.
Higher boiler pressures require feed water to enter at higher temperatures to prevent structural stresses.
Reduces the thermal load on the boiler drum.
Improved overall boiler thermal efficiency
Reduction in fuel consumption costs
Reduces internal stresses in boiler drums
Lower flue gas exhaust temperature
Increased capital cost of the power plant
Possibility of flue gas side corrosion if temperature drops below dew point
Additional pressure drop in the flue gas path
Thermal power plants
Large scale industrial boilers
Combined Heat and Power (CHP) plants
An economizer is mandatory in modern high-pressure power plants because the difference between the saturation temperature of water and ambient feed water temperature is high, leading to significant thermal strain.
If the temperature of flue gas drops below the dew point, sulfuric acid can condense, causing severe corrosion of the economizer tubes.
D is correct тАФ The economizer significantly improves efficiency, reduces fuel consumption, and is critical for managing thermal stresses in high-pressure steam power plants.
Always remember that in steam power plants, components like economizers and air preheaters are specifically designed to reduce the 'Heat Rate' by recycling energy that would otherwise be lost to the environment.