In a surface condenser, on removal of air
Absolute pressure of condenser is reduced
Absolute pressure of condenser is increased
Absolute pressure of condenser remains unaffected
Temperature of condensed steam is increased
Absolute pressure of condenser is reduced
According to Dalton's Law of Partial Pressures, the total pressure in a condenser is the sum of the partial pressures exerted by the steam and the non-condensable air. Removing the air reduces the partial pressure component contributed by it, thereby lowering the overall absolute pressure inside the condenser.
According to Dalton's Law of Partial Pressures, the total pressure in a condenser is the sum of the partial pressures exerted by the steam and the non-condensable air. Removing the air reduces the partial pressure component contributed by it, thereby lowering the overall absolute pressure inside the condenser.
PtotalтАЛ=PsтАЛ+PaтАЛ тАФ Where PsтАЛ is partial pressure of steam and PaтАЛ is partial pressure of air.
The total pressure PtotalтАЛ is defined as PsteamтАЛ+PairтАЛ. In a surface condenser, air acts as a non-condensable impurity that increases the total pressure above the saturation pressure corresponding to the steam temperature. By using an air extraction pump (vacuum pump) to remove this air, the value of PairтАЛ decreases, which forces the total pressure PtotalтАЛ toward the saturation pressure of the steam, effectively creating a deeper vacuum.
Presence of air acts as an insulator, reducing the heat transfer coefficient.
Air extraction is essential to maintain high vacuum efficiency in steam power plants.
The partial pressure of air is the primary cause of condenser pressure deviation from the theoretical steam table vacuum.
Removal of air increases the overall thermal efficiency of the Rankine cycle.
Improved heat transfer rates
Higher vacuum levels
Reduced corrosion in condenser tubes
Increases auxiliary power consumption due to vacuum pump operation
System complexity increases
Steam Power Plants
Desalination Units
Refrigeration Cycles
The air is typically removed using steam jet ejectors or liquid ring vacuum pumps.
Option B is incorrect because air removal does not increase absolute pressure; it lowers it.
Option C is incorrect because air significantly influences total pressure in a closed vessel.
Option D is incorrect as temperature is primarily determined by the steam table saturation point, which does not necessarily rise upon air removal.
A is correct тАФ The removal of air reduces the partial pressure component, resulting in a decrease in the absolute pressure of the condenser.
Always remember that in any system where non-condensable gases exist, they contribute to the total gauge pressure; removing them is the standard method for improving vacuum levels in thermal equipment.