In DC shunt motor if the load is increased, the speed
increased slightly
reduce slightly
remains constant
increase proportional
reduce slightly
In a DC shunt motor, the speed decreases slightly as the load increases because of the voltage drop across the armature resistance (IaтАЛRaтАЛ drop). Since the shunt field is connected in parallel to the supply, the flux remains essentially constant, but the back EMF must adjust to meet the increased torque demand.
In a DC shunt motor, the speed decreases slightly as the load increases because of the voltage drop across the armature resistance (IaтАЛRaтАЛ drop). Since the shunt field is connected in parallel to the supply, the flux remains essentially constant, but the back EMF must adjust to meet the increased torque demand.
N=K╬жVтИТIaтАЛRaтАЛтАЛ тАФ Relationship between speed and load parameters
EbтАЛ=VтИТIaтАЛRaтАЛ тАФ Back EMF equation for DC shunt motor
The speed of a DC motor is governed by the equation NтИЭ╬жEbтАЛтАЛ. As mechanical load increases, the armature current (IaтАЛ) rises to develop the required torque (TтИЭ╬жIaтАЛ). This higher current causes a larger voltage drop (IaтАЛRaтАЛ) across the armature, which reduces the back EMF (EbтАЛ=VтИТIaтАЛRaтАЛ). Consequently, the motor speed drops slightly to maintain the balance of the equation.
The DC shunt motor is essentially a constant-speed motor.
The speed regulation of a shunt motor is very low.
Armature reaction at high loads can slightly modify the speed-load profile.
Constant speed operation under varying loads
Easy speed control via field or armature resistance
Starting torque is lower compared to series motors
Sensitive to supply voltage fluctuations
Lathe machines
Centrifugal pumps
Fans and Blowers
The drop in speed is approximately 3-5% from no-load to full-load.
Option A is incorrect because the motor does not accelerate with load; Option C is inaccurate as it implies perfect speed regulation, which is physically impossible due to resistance.
B is correct тАФ The DC shunt motor exhibits a slight reduction in speed as load increases due to the internal IaтАЛRaтАЛ voltage drop.
Always remember that 'Shunt' implies constant flux, while 'Series' implies speed varies inversely with the square of the current.