Join 60,000+ competitive exam aspirants
In one 132/33 kV transformer the LV resistance is 0.02 per unit. The resistance referred to the HV side is
32 pu
02 pu
00125 pu
None of the all
02 pu
In power transformer analysis using the per-unit (pu) system, the resistance value remains invariant when referred from one side of the transformer to the other. Since the per-unit system normalizes values to the specific base of each side, the pu impedance/resistance is independent of the turns ratio.
In power transformer analysis using the per-unit (pu) system, the resistance value remains invariant when referred from one side of the transformer to the other. Since the per-unit system normalizes values to the specific base of each side, the pu impedance/resistance is independent of the turns ratio.
Rpu(HV)тАЛ=Rpu(LV)тАЛ тАФ The principle of invariance in per-unit system
ZbaseтАЛ=SbaseтАЛVbase2тАЛтАЛ тАФ Base impedance calculation
The per-unit impedance ZpuтАЛ is defined as ZpuтАЛ=ZbaseтАЛZactualтАЛтАЛ. Given ZbaseтАЛ=SbaseтАЛVbase2тАЛтАЛ, both the HV and LV sides use the same power base SbaseтАЛ and their respective voltage bases VbaseтАЛ satisfy the transformer turns ratio. Consequently, the ohmic value transformed by the square of the turns ratio a2 is perfectly compensated by the change in the base impedance, resulting in the same pu value on both sides.
Per-unit quantities are dimensionless and independent of the transformer turns ratio.
The resistance of 0.02 pu on the LV side will be exactly 0.02 pu when referred to the HV side.
Using pu values simplifies calculations in power systems by eliminating the need to reflect impedances across transformers.
Simplifies power system network calculations.
Eliminates the need to transform impedances across voltage levels.
Requires careful identification of the common MVA base.
Can be confusing if base values are not clearly defined.
Short circuit studies.
Power flow analysis in multi-voltage level grids.
Transformer impedance modeling.
The per-unit system is highly preferred in industry as it makes transformer turn ratios 'disappear' in circuit equations.
Option A and C are incorrect because they suggest the resistance changes value when referred, which contradicts the definition of the per-unit system.
B is correct тАФ In the per-unit system, the resistance value remains numerically the same on both the LV and HV sides of a transformer.
Always remember that pu values are designed to be scale-invariant; if you are asked to refer a pu impedance, it is a trick questionтАФthe value stays the same!