In the Ward-Leonard system, the lower limit of the speed imposed by
Field resistance
Armature resistance
Residual magnetism of the generator
None of the above
Residual magnetism of the generator
The Ward-Leonard system provides wide speed control by varying the generator voltage. The lower speed limit is dictated by the residual magnetism present in the generator field poles, which generates a small voltage even when the field current is reduced to zero.
The Ward-Leonard system provides wide speed control by varying the generator voltage. The lower speed limit is dictated by the residual magnetism present in the generator field poles, which generates a small voltage even when the field current is reduced to zero.
EgтАЛ=P╬жNZ/(60A) тАФ EMF induced in generator armature
╧ЙmтАЛтИЭVaтАЛ тАФ Motor speed proportional to armature voltage
In the Ward-Leonard scheme, the armature of the main DC motor is fed by a separate DC generator. The speed of the main motor is proportional to the armature voltage VaтАЛ=EgтАЛтИТIaтАЛRaтАЛ. When the generator field current is reduced to zero, the motor does not stop completely because the residual flux ╬жresтАЛ induces a residual EMF EresтАЛ in the generator, causing the motor to continue rotating at a very low speed.
Ward-Leonard system allows smooth speed control from zero to rated speed and beyond.
It is a constant torque drive system.
The residual magnetism defines the absolute lower limit of controlled speed in a basic Ward-Leonard setup.
To reach zero speed, a negative excitation (bucking field) is required to neutralize the residual flux.
Very wide speed control range
Smooth and precise speed regulation
Excellent braking characteristics (regenerative braking)
High initial cost due to three machines (Motor-Generator set + Main motor)
Low overall efficiency due to multiple energy conversions
Requires significant floor space
Rolling mills
Colliery winders
Large excavators and elevators
To eliminate the residual magnetism effect, an 'opposing' or 'bucking' field current is often applied.
Option B (Armature resistance) is used for speed control but leads to high I2R losses and is not the limit factor for the system range itself.
C is correct тАФ The residual magnetism of the generator field poles induces a residual voltage in the armature, which prevents the motor speed from dropping to absolute zero without further modifications.
Always remember that in any DC shunt/separately excited machine, 'zero speed' is theoretical unless external circuitry is used to counteract residual voltage.