Join 60,000+ competitive exam aspirants
Ward-Leonard control is basically a ___________ control method.
Field control
Armature resistance control
Armature voltage control
Field diverter control
Armature voltage control
Ward-Leonard control is a method used for smooth and wide-range speed control of DC motors by varying the armature voltage applied to the motor. It employs a motor-generator set (M-G set) where the output voltage of the generator is adjusted to control the speed of the main DC motor.
Ward-Leonard control is a method used for smooth and wide-range speed control of DC motors by varying the armature voltage applied to the motor. It employs a motor-generator set (M-G set) where the output voltage of the generator is adjusted to control the speed of the main DC motor.
EbтАЛ=VaтАЛтИТIaтАЛRaтАЛ тАФ Back EMF equation
NтИЭ╬жVaтАЛтАЛ тАФ Speed relationship where VaтАЛ is armature voltage
The system consists of a prime mover driving a DC generator. By adjusting the field excitation of the generator using a potentiometer, its output terminal voltage is varied. This variable voltage is fed to the armature of the main DC motor, which directly regulates its speed according to the relation NтИЭ╬жVaтАЛтИТIaтАЛRaтАЛтАЛ.
Provides extremely smooth speed control from zero to maximum speed in both directions.
The inherent speed regulation of the motor is excellent.
Commonly used in steel rolling mills, mine hoists, and electric excavators.
It is a constant torque, constant power drive method depending on the range of control.
Wide speed range
Smooth and stepless speed control
Excellent speed regulation
Capable of regeneration (braking)
High initial cost due to M-G set
Lower overall efficiency, especially at light loads
Requires more floor space and maintenance
Rolling mills
Mine hoists
Electric excavators
Paper machines
The method is essentially an armature voltage control method.
Option B (Armature resistance control) is inefficient due to high I2R losses.
Option D (Field diverter) is used for series motors and provides limited control range.
C is correct тАФ Ward-Leonard control is essentially an armature voltage control method for DC motors.
Always remember that field control is used for speeds above base speed, while armature voltage control (like Ward-Leonard) is preferred for speeds below base speed.