In which of the following DC Motor the ratio of starting torque to full load torque is minimum?
Shunt motor
Series motor
Differential compound motor
Cumulative compound motor
Differential compound motor
The starting torque of a DC motor is directly proportional to the flux per pole (╬ж) and the armature current (IaтАЛ). In a differential compound motor, the series field flux opposes the shunt field flux, leading to a reduced net flux at startup, which results in the minimum starting torque compared to other DC motor configurations.
The starting torque of a DC motor is directly proportional to the flux per pole (╬ж) and the armature current (IaтАЛ). In a differential compound motor, the series field flux opposes the shunt field flux, leading to a reduced net flux at startup, which results in the minimum starting torque compared to other DC motor configurations.
TaтАЛтИЭ╬жIaтАЛ тАФ Torque expression for DC motor
╬жnetтАЛ=╬жshтАЛ┬▒╬жseтАЛ тАФ Flux summation in compound machines
In a differential compound motor, the total flux is given by ╬ж=╬жshuntтАЛтИТ╬жseriesтАЛ. At the moment of starting, the high inrush armature current flows through the series field winding, creating a strong opposing flux that significantly weakens the total magnetic field. Since torque TтИЭ╬жIaтАЛ, this reduction in total flux ╬ж minimizes the starting torque capability of the machine.
Differential compound motors are rarely used in practice due to the risk of instability at high loads.
Series motors provide the highest starting torque due to ╬жтИЭIaтАЛ giving TтИЭIa2тАЛ.
Shunt motors provide moderate starting torque.
Cumulative compound motors provide higher starting torque than shunt motors due to the aiding series field.
Useful for specific applications requiring constant speed under varying load conditions.
Can be designed to have zero speed regulation.
Highly unstable at heavy loads (danger of speed reversal).
Low starting torque.
Poor performance during transient overloads.
Rarely used in industrial applications.
Academic and experimental setups for studying flux cancellation.
| Feature | Descending Order | Minimum |
|---|---|---|
Starting Torque Ranking | Series > Cumulative > Shunt > Differential | Min: Differential |
The Differential Compound motor can potentially reverse its direction of rotation if the load increases significantly, as the series flux may exceed the shunt flux.
Option B (Series motor) is the exact opposite; it provides the maximum starting torque among all DC motors.
C is correct тАФ The differential compound motor has the minimum starting torque because the series field flux opposes the shunt field flux, reducing the total magnetic field.
Always remember that 'Differential' implies subtraction of fields, while 'Cumulative' implies addition; this rule applies to both motors and generators.