Induced draught fans are used to
Cool the steam let out by the turbine in thermal station
Cool the hot gases coming out of the boiler
Force the air inside the coal furnace
Control the heat generated in a nuclear reactor
Force the air inside the coal furnace
Induced draught (ID) fans are mechanical devices installed at the exit of a boiler, typically near the chimney, to extract hot flue gases from the furnace and discharge them into the atmosphere. By creating a negative pressure (vacuum) within the boiler furnace, they ensure the continuous flow of combustion air and exhaust gases, which is essential for efficient coal combustion.
Induced draught (ID) fans are mechanical devices installed at the exit of a boiler, typically near the chimney, to extract hot flue gases from the furnace and discharge them into the atmosphere. By creating a negative pressure (vacuum) within the boiler furnace, they ensure the continuous flow of combustion air and exhaust gases, which is essential for efficient coal combustion.
PdraftтАЛ=╧БтЛЕgтЛЕHтЛЕ(TatmтАЛ1тАЛтИТTgasтАЛ1тАЛ) тАФ represents the natural draft pressure; ID fans supplement this when combustion resistance is high.
Q=AтЛЕv тАФ indicates that volumetric flow rate Q is proportional to the velocity v induced by the fan pressure drop.
The ID fan acts as a suction mechanism. By reducing the furnace pressure below atmospheric pressure, it draws fresh air through the air preheaters and fuel bed. The pressure difference ╬ФP=PatmтАЛтИТPfurnaceтАЛ drives the flow of combustion gases through the economizer and air preheater before being expelled via the stack.
ID fans are located between the air preheater and the chimney.
They create negative pressure (suction) in the furnace.
They are critical for handling high-density flue gases in large-scale boilers.
ID fans must be designed to withstand high temperatures of exhaust gases.
Enables burning of various coal qualities by precise airflow control.
Reduces leakage of furnace gases into the boiler room environment.
High power consumption due to large volumetric flow requirements.
Maintenance cost is high due to erosion and high-temperature operation.
Thermal power plants using coal-fired boilers.
Industrial incinerators and large steam generators.
Forced Draught (FD) fans push air into the furnace, while Induced Draught (ID) fans pull air through the system.
Option A relates to the condenser, Option B is a misinterpretation of the heat recovery process, and Option D is specific to nuclear reactor cooling systems.
C is correct тАФ Induced draught fans create a negative pressure to effectively pull the combustion gases through the system and out of the chimney.
Always remember the mnemonic 'FD for Pushing (Forcing)' and 'ID for Pulling (Inducing)' air through the power plant's flue gas path.