Join 60,000+ competitive exam aspirants
Integrated load duration curve representing total number of units generated for a given demand can be plotted directly from
Load curve
Load duration curve
Mass curve
Any of above
Load duration curve
The Integrated Load Duration Curve (ILDC), also known as the energy load curve, is derived by integrating the load duration curve. It represents the total number of energy units (in kWh) generated for any given demand level.
The Integrated Load Duration Curve (ILDC), also known as the energy load curve, is derived by integrating the load duration curve. It represents the total number of energy units (in kWh) generated for any given demand level.
E=тИл0TтАЛP(t)dt тАФ represents energy as the integral of power over time.
Capacity┬аFactor=MaxDemand├ЧTimeActualEnergyProducedтАЛ тАФ efficiency metric derived from area under the curve.
The Load Duration Curve (LDC) plots the load against time, with values arranged in descending order. When the area under the LDC is integrated from the peak demand down to a specific load value, the resulting curve gives the cumulative energy generated. This helps in determining the capacity factors for base load and peak load plants.
The Load Duration Curve shows the time duration for which a particular load is exceeded.
The area under the Load Duration Curve represents total energy generated.
The Integrated Load Duration Curve is essentially the cumulative distribution function of the load.
It is primarily used for economic scheduling of power plants.
Helps in selecting the size and number of generating units.
Clearly shows the portion of load that is base-load vs peak-load.
Simplifies calculation of energy cost per unit.
Loses information regarding the specific time of occurrence of the load.
Cannot be used to determine the exact peak demand timing (unlike a chronological load curve).
Planning of thermal, hydro, and nuclear power plant capacity.
Determining the reserve capacity of a power system.
The chronological load curve provides the sequence of events but is less convenient for finding total energy or plant capacity requirements.
The mass curve is typically used in hydraulic engineering for water storage calculations, not directly for plotting electrical load energy.
B is correct тАФ The integrated load duration curve is mathematically derived from the load duration curve to show the total units (energy) generated.
Remember that the area under a standard Load Duration Curve gives energy, while the 'Integrated' curve represents the summation of that energy starting from the highest load.