Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Lowest occurred fault in overhead line is

A

LG

B

LL

C

LLG

D

LLL

Correct Answer

Concept & PrincipleElectricalPower System
Option D

LLL

Quick Summary: Three-phase symmetrical (LLL) faults are the least frequent occurrences in overhead power transmission lines. Statistically, approximately 70-80% of all power system faults are single line-to-ground (LG) faults, while symmetrical three-phase faults account for less than 5% of total faults.

💡 Explanation

Three-phase symmetrical (LLL) faults are the least frequent occurrences in overhead power transmission lines. Statistically, approximately 70-80% of all power system faults are single line-to-ground (LG) faults, while symmetrical three-phase faults account for less than 5% of total faults.

🔢 Key Formulas

Pfault∝Zfault−1P_{fault} \propto Z_{fault}^{-1}Pfault​∝Zfault−1​ — Relationship between fault current and system impedance

Isym=VphZ1I_{sym} = \frac{V_{ph}}{Z_1}Isym​=Z1​Vph​​ — Symmetrical fault current calculation

⚙️ Working Principle

Overhead lines are subjected to various external disturbances like wind, falling trees, and lightning. LG faults are most common because they involve only one phase-to-ground insulation breakdown. Conversely, LLL faults require simultaneous contact or insulation failure of all three phases, which is statistically improbable due to the physical separation between conductors and the complexity of such a coincidental event.

📌 Key Points
  • ▸

    LG faults are the most common (approx. 70-80%).

  • ▸

    LL faults account for approx. 10-15%.

  • ▸

    LLG faults account for approx. 5-10%.

  • ▸

    LLL faults are the least common (< 5%) but the most severe.

✅ Advantages
  • ▸

    Symmetrical faults are easiest to calculate using the per-unit system.

  • ▸

    Easier design for protection relays since they rely on balanced conditions.

❌ Disadvantages / Limitations
  • ▸

    LLL faults cause maximum mechanical stress on transmission towers.

  • ▸

    Extreme thermal stress on circuit breakers during current interruption.

🛠️ Applications / Uses
  • ▸

    System stability studies.

  • ▸

    Circuit breaker rating selection.

📄 Additional Information
  • ▸

    Symmetrical faults are also known as 'balanced faults' because the system remains balanced after the fault occurs.

  • ▸

    Option A (LG) is the most frequent fault type, not the lowest.

📊 Diagram / Illustration
Fault Frequency DistributionLG (Max)LLLLGLLL (Min)
✅

D is correct — The three-phase (LLL) fault is the rarest type of fault occurring in overhead transmission lines.

Core Concepts Used
Click any tag to open in AI Tutor
Symmetrical vs Unsymmetrical faults Power System Protection Fault Statistics
💡 EXAM TIP

Remember the hierarchy: LG > LL > LLG > LLL for frequency, but LLL > LLG > LL > LG for severity of current magnitude.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______

Discussion (0)