Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Most occurred fault in overhead line is

A

LG

B

LL

C

LLG

D

LLL

Correct Answer

Concept & PrincipleElectricalPower System
Option A

LG

Quick Summary: The most frequently occurring fault in overhead power transmission and distribution lines is the Line-to-Ground (LG) fault. Statistically, approximately 70-80% of all system faults are LG faults, usually caused by transient events such as lightning strikes or flashovers due to tree branches or pollution.

💡 Explanation

The most frequently occurring fault in overhead power transmission and distribution lines is the Line-to-Ground (LG) fault. Statistically, approximately 70-80% of all system faults are LG faults, usually caused by transient events such as lightning strikes or flashovers due to tree branches or pollution.

🔢 Key Formulas

If=VphZ1+Z2+Z0I_{f} = \frac{V_{ph}}{Z_{1} + Z_{2} + Z_{0}}If​=Z1​+Z2​+Z0​Vph​​ — Represents the fault current for an LG fault in a three-phase system using symmetrical components.

⚙️ Working Principle

An LG fault occurs when a single phase conductor makes contact with the ground or a grounded structure (like a tower or pole). This can be caused by insulation breakdown, wind-blown debris, or external objects. Because the earth provides a low-impedance path, a large fault current flows through the ground back to the system neutral, which is detected by protective relays to trigger circuit breaker operation.

📌 Key Points
  • ▸

    LG faults account for 70-80% of total faults.

  • ▸

    LL faults account for 10-15% of total faults.

  • ▸

    LLG faults account for 5-10% of total faults.

  • ▸

    LLL faults are the rarest (approx. 2-5%) but are the most severe.

✅ Advantages
  • ▸

    Most LG faults are transient in nature.

  • ▸

    System stability is easier to maintain compared to symmetrical faults.

❌ Disadvantages / Limitations
  • ▸

    Requires high-speed clearing to prevent equipment damage.

  • ▸

    Can lead to significant voltage dips.

🛠️ Applications / Uses
  • ▸

    Used in designing relay coordination settings for distance and overcurrent protection.

🔄 Comparison Table
FeatureLG (Common)LLL (Severe)

Fault Type

70-80%

2-5%

📄 Additional Information
  • ▸

    LLL (Three-phase to ground) faults are considered symmetrical and are the most severe, involving all three phases.

  • ▸

    The sequence network for an LG fault involves connecting the positive, negative, and zero sequence networks in series.

📊 Diagram / Illustration
Fault Frequency DistributionLGLLLLGLLL
✅

A is correct — The LG (Line-to-Ground) fault is the most common fault in overhead transmission systems due to its sensitivity to external environmental disturbances.

Core Concepts Used
Click any tag to open in AI Tutor
Symmetrical Components Power System Stability Fault Analysis
💡 EXAM TIP

Always remember the order of frequency: LG > LL > LLG > LLL; however, remember that the order of severity (current magnitude) is exactly the inverse: LLL > LLG > LL > LG.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______