Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Merz prize protection system is used for

A

Transformer

B

Alternator

C

Both A and B

D

None of above

Correct Answer

Concept & PrincipleElectricalPower System
Option C

Both A and B

Quick Summary: The Merz-Price protection system is a form of unit protection (differential protection) based on the principle of circulating currents. It is widely used to provide high-speed, selective protection for both power transformers and AC generators (alternators) against internal faults.

💡 Explanation

The Merz-Price protection system is a form of unit protection (differential protection) based on the principle of circulating currents. It is widely used to provide high-speed, selective protection for both power transformers and AC generators (alternators) against internal faults.

🔢 Key Formulas

Idiff=∣I1−I2∣=0I_{diff} = |I_1 - I_2| = 0Idiff​=∣I1​−I2​∣=0 (Normal Condition)

Idiff=∣I1−I2∣≠0I_{diff} = |I_1 - I_2| \neq 0Idiff​=∣I1​−I2​∣=0 (Fault Condition)

⚙️ Working Principle

The system compares the current entering and leaving the protected zone using Current Transformers (CTs). Under healthy conditions, the secondary currents circulate between CTs such that the net current through the relay is zero. During an internal fault, the balance is disrupted, causing a differential current to flow through the relay, which triggers the circuit breaker.

📌 Key Points
  • ▸

    It is also known as the Biased Differential Protection system when used with a restraining coil.

  • ▸

    The CTs at both ends must have identical ratios and phase characteristics.

  • ▸

    It provides instantaneous clearing of faults within the protected zone.

  • ▸

    Used extensively for large machines where high-speed protection is mandatory.

✅ Advantages
  • ▸

    High-speed operation

  • ▸

    Provides inherent selectivity (only clears faults within the protected zone)

  • ▸

    No time-delay grading required

❌ Disadvantages / Limitations
  • ▸

    Requires pilot wires for communication between distant CTs

  • ▸

    Susceptible to mal-operation due to CT saturation during external through-faults

🛠️ Applications / Uses
  • ▸

    Large Alternator winding protection

  • ▸

    Power Transformer differential protection

📄 Additional Information
  • ▸

    The system is often referred to as 'Merz-Price' (or Mertz-Price).

  • ▸

    The protection is limited to the zone between the two sets of CTs.

📊 Diagram / Illustration
Merz-Price Circulating Current PrincipleCT (Input)CT (Output)RelayIᴅᵢ𝆩𝆩 = I₁ - I₂
✅

C is correct — Merz-Price protection is a differential protection scheme applicable to both transformer and alternator windings.

Core Concepts Used
Click any tag to open in AI Tutor
Differential Protection Circulating Current Principle Fault Detection
💡 EXAM TIP

Always remember that 'Unit Protection' schemes like Merz-Price do not require coordination with other relays, unlike 'Non-unit' schemes like Overcurrent protection.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______