Examoogle
ExamsTest SeriesRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
🛒0
अA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
© 2026 Examoogle. India's #1 competitive exam AI tutor.
🔒 SSL Secured📱 UPI Accepted🧾 GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
Subtotal₹0
Total₹0
Examoogle • User • info@examoogle.com • EE-2024-8821
Chapter 1 of 12 • Page 1 of 248🔒 Protected PDF • Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Merz prize protection system works on principle of

A

Current balance

B

Voltage balance

C

Power balance

D

None of above

Correct Answer

Concept & PrincipleElectricalPower System
Option A

Current balance

Quick Summary: The Merz-Price protection system, also known as Differential Protection, operates on the principle of circulating current or current balance. It compares the current entering and leaving the protected zone (such as a generator or transformer); under normal conditions, the currents are equal, resulting in zero net current in the relay coil.

💡 Explanation

The Merz-Price protection system, also known as Differential Protection, operates on the principle of circulating current or current balance. It compares the current entering and leaving the protected zone (such as a generator or transformer); under normal conditions, the currents are equal, resulting in zero net current in the relay coil.

🔢 Key Formulas

Idiff=∣I1⃗−I2⃗∣I_{diff} = |\vec{I_1} - \vec{I_2}|Idiff​=∣I1​​−I2​​∣ — differential current representing the relay operating condition

I1=I2I_1 = I_2I1​=I2​ — normal operating condition (no fault)

⚙️ Working Principle

In this scheme, current transformers (CTs) are placed at both ends of the protected equipment. If a fault occurs, the currents at the two ends become unequal, causing a differential current to flow through the relay, which triggers the circuit breaker. This system is inherently fast and selective because it only reacts to faults within the protected zone.

📌 Key Points
  • ▸

    It is primarily used for the protection of generators and large transformers.

  • ▸

    It is a unit protection system, meaning it only protects the specific equipment between the CTs.

  • ▸

    The pilot wires connect the secondary windings of CTs at both ends in a circulating current arrangement.

✅ Advantages
  • ▸

    High speed of operation.

  • ▸

    Excellent discrimination between internal and external faults.

❌ Disadvantages / Limitations
  • ▸

    Requirement of pilot wires between the ends of the equipment.

  • ▸

    Sensitivity to CT saturation errors under heavy external faults.

🛠️ Applications / Uses
  • ▸

    Generator winding protection

  • ▸

    Power transformer winding protection

  • ▸

    Busbar protection

📄 Additional Information
  • ▸

    Option B (Voltage balance) is the principle behind the Translay system, not Merz-Price.

  • ▸

    The term 'current balance' refers to the comparison of magnitudes and phase angles of currents entering and leaving the protected zone.

📊 Diagram / Illustration
Merz-Price Differential PrincipleCT at End 1CT at End 2Relay CoilIᴅᵢ𝆩𝆩 = I₁ - I₂
✅

A is correct — Merz-Price protection works on the principle of circulating current or current balance, where the difference between input and output currents triggers the relay.

Core Concepts Used
Click any tag to open in AI Tutor
Differential Protection Unit Protection Current Transformers
💡 EXAM TIP

Always remember that Merz-Price uses a circulating current arrangement, while the Translay system utilizes an opposing voltage arrangement.

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______