Metallic shielding is provided on underground cables to
Reduce thermal resistance
Reduce corona effect
Control the electrostatic voltage stress
All of above
Reduce thermal resistance
Metallic shielding (usually lead or copper) is placed over the insulation of high-voltage underground cables to ensure uniform radial electric stress distribution and provide a low-resistance path for fault currents. It essentially traps the electrostatic field within the cable, protecting the cable insulation from ionization and external interference.
Metallic shielding (usually lead or copper) is placed over the insulation of high-voltage underground cables to ensure uniform radial electric stress distribution and provide a low-resistance path for fault currents. It essentially traps the electrostatic field within the cable, protecting the cable insulation from ionization and external interference.
E=rln(R/r)VтАЛ тАФ Electrostatic stress at radius r
C=ln(R/r)2╧А╧╡0тАЛ╧╡rтАЛтАЛ тАФ Capacitance of single-core cable
The shield acts as an equipotential surface, forcing the electric field lines to be purely radial, which prevents local concentration of stress at imperfections. By effectively grounding the outer layer of the insulation, it eliminates the tangential stress that would otherwise cause partial discharges and insulation breakdown. Additionally, the metallic sheath facilitates heat dissipation by providing a conductive path to the surrounding medium.
Metallic shielding provides a return path for fault current, allowing protective relays to operate quickly.
It prevents the cable from becoming a source of electromagnetic interference (EMI) to communication circuits.
The shield helps in keeping the insulation surface at ground potential, ensuring safety for personnel.
It reduces the thermal resistance by allowing heat to distribute uniformly along the circumference.
Uniform distribution of dielectric stress
Enhanced protection against insulation breakdown
Improved safety for nearby communication lines
Increases the overall manufacturing cost
Adds weight and complexity to cable installation
Requires careful grounding to prevent sheath circulating currents
High voltage underground transmission lines
Submarine power cables
Industrial distribution networks where EMI is a concern
In cables rated above 5 kV, shielding is mandatory to prevent tracking and treeing.
Option A is correct because the metallic sheath improves the thermal path from the insulation to the exterior.
D is correct тАФ Metallic shielding improves underground cable performance by managing thermal dissipation, mitigating corona/partial discharge, and ensuring uniform electrostatic field distribution.
Always remember that metallic shielding is strictly required for cables where the insulation is susceptible to ionization at high electric field gradients (typically > 5 kV).