Join 60,000+ competitive exam aspirants
No-load saturation characteristics are plotted between
no-load voltage and field current
no-load voltage and armature current
short circuit current and field current
short circuit current and armature current
no-load voltage and field current
The no-load saturation characteristic (also known as the Open Circuit Characteristic, OCC) of a DC machine represents the relationship between the generated emf E0тАЛ and the field current IfтАЛ at constant rated speed. It depicts how the magnetic flux density changes as the field excitation increases, showing the non-linear transition from the linear magnetic region to the saturation region.
The no-load saturation characteristic (also known as the Open Circuit Characteristic, OCC) of a DC machine represents the relationship between the generated emf E0тАЛ and the field current IfтАЛ at constant rated speed. It depicts how the magnetic flux density changes as the field excitation increases, showing the non-linear transition from the linear magnetic region to the saturation region.
E0тАЛ=kaтАЛ╬ж╧Й тАФ Where kaтАЛ is machine constant, ╬ж is flux per pole, and ╧Й is angular velocity.
╬жтИЭIfтАЛ тАФ Representing the linear region of magnetization before saturation.
The characteristic is obtained by running the DC machine as a generator at a constant rated speed with no load connected (armature current IaтАЛ=0). As the field current IfтАЛ is varied, the flux ╬ж changes, resulting in a proportional change in the induced emf E0тАЛ=k╬ж╧Й. Due to the magnetic properties of the iron core, the curve follows the magnetization path of the material.
The curve is plotted at constant rated speed.
The initial straight portion is due to the reluctance of the air gap.
The curvature (bending) occurs due to the saturation of iron poles and teeth.
The intercept on the Y-axis represents the residual magnetism voltage.
Determines the voltage build-up capability of a shunt generator.
Useful for calculating the critical resistance and critical speed.
Does not account for armature reaction effects.
Requires constant speed maintenance throughout the test.
Determination of critical field resistance.
Calibration of DC generators for specific voltage requirements.
The OCC is also referred to as the Magnetization Curve.
Option B is wrong because armature current is zero at no-load.
Options C and D refer to short-circuit characteristics, used to find armature reaction and synchronous impedance.
A is correct тАФ The no-load saturation characteristic represents the variation of generated EMF (E0тАЛ) with respect to field current (IfтАЛ) at a constant rated speed.
Always remember that OCC relates E0тАЛ and IfтАЛ at zero load, whereas SCC (Short Circuit Characteristic) relates IaтАЛ and IfтАЛ at zero voltage.