What is/are the necessary conditions for voltage build up in a self-excited generator?
Poles should contain residual flux
Field winding should be properly connected to the armature winding
Field winding resistance should be less than critical resistance
All of the above
All of the above
For a self-excited DC generator to initiate voltage build-up, it requires an initial residual magnetic field to induce a small EMF upon rotation, correct polarity of field winding connections to ensure positive feedback, and a field circuit resistance lower than the critical resistance to ensure the cumulative process continues.
For a self-excited DC generator to initiate voltage build-up, it requires an initial residual magnetic field to induce a small EMF upon rotation, correct polarity of field winding connections to ensure positive feedback, and a field circuit resistance lower than the critical resistance to ensure the cumulative process continues.
EgтАЛ=K╬ж╧Й тАФ Induced EMF in armature
RcтАЛ=IfтАЛVтАЛ at saturation point тАФ Critical resistance condition
As the armature rotates, the residual flux induces a small EMF, which drives a current through the field winding. If the winding is connected to provide positive feedback (cumulative), the resulting flux increases the armature EMF, leading to more current. This self-reinforcing cycle continues until the iron saturates, provided the circuit resistance does not dissipate more power than the machine can generate at that specific speed.
Residual magnetism is essential to start the induction process at t=0.
If field connections are reversed, the induced EMF opposes the residual flux, preventing voltage build-up (demagnetization).
The critical resistance is the maximum resistance of the field circuit beyond which the generator fails to build voltage.
Voltage build-up is also dependent on the speed of the prime mover; it must exceed the critical speed.
Self-contained operation (no external DC source needed)
Automatic voltage adjustment with load variations (in compound types)
Vulnerable to loss of residual magnetism
Requires maintenance of critical speed and resistance parameters
Battery charging
DC arc welding
Excitation systems for AC generators
If a generator loses its residual flux, it can be restored by 'flashing the field' using an external DC supply.
Option B refers to the connection polarity; if the connection results in negative feedback, the terminal voltage will drop rather than build up.
D is correct тАФ All listed factors are essential constraints for the self-excitation process of a DC generator.
Always verify the polarity (cumulative vs. differential) when dealing with DC machine connections, as it determines whether the machine functions as a generator or stalls.