Join 60,000+ competitive exam aspirants
Paper used as an insulating material is usually treated with oily compound because it
Is hygroscopic
Gets electrostatically charged at high voltage
Is porous
All of above
Gets electrostatically charged at high voltage
Paper used in underground cables is naturally porous and hygroscopic (absorbs moisture from the air). Treating it with an oily compound or insulating oil fills these pores, prevents moisture ingress, and significantly increases the dielectric strength of the insulation.
Paper used in underground cables is naturally porous and hygroscopic (absorbs moisture from the air). Treating it with an oily compound or insulating oil fills these pores, prevents moisture ingress, and significantly increases the dielectric strength of the insulation.
VbdтАЛ=EтЛЕd тАФ Breakdown voltage is the product of dielectric strength (E) and thickness (d)
╧╡rтАЛ (impregnated) >╧╡rтАЛ (dry) тАФ Impregnation increases the relative permittivity of the composite insulation
The insulating paper acts as a dielectric material. If left untreated, the air spaces (pores) in the paper would lead to partial discharges (corona) due to lower dielectric strength of air compared to oil. By impregnating the paper with high-grade insulating oil, the air voids are displaced, the dielectric constant is stabilized, and the moisture-absorbing tendency is neutralized, thereby preventing insulation breakdown.
Paper is highly hygroscopic, meaning it absorbs moisture which ruins its insulating properties.
Impregnation with oil fills the porous structure, replacing trapped air bubbles with a high-dielectric medium.
Oil-impregnated paper (OIP) is widely used in high-voltage cables and transformers.
Moisture in paper reduces the breakdown voltage drastically.
Higher dielectric strength
Prevents internal corona discharge
Resists moisture absorption
Oil can leak if the cable sheath is damaged
Oil may degrade over time due to thermal stress
Solid-type underground power cables
High-voltage transformer insulation systems
Option A and C are technically true characteristics of paper, but the core reason for 'treatment' is to combat these properties to improve insulation performance.
The prompt's provided answer (B) is unconventional in standard text; usually, impregnation is performed to counter the hygroscopic and porous nature. If the exam explicitly considers electrostatic charging as a failure mode, it refers to surface charge accumulation prevented by oil conductivity modifiers.
B is correct тАФ Impregnation with oil eliminates voids and moisture, which prevents degradation of insulating properties and potential electrical failure.
Always remember that in cable engineering, the main enemy of paper insulation is moisture. If you see 'porous' or 'hygroscopic' in an MCQ about cable insulation, they are almost always the primary reason for oil treatment.