Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalBasic Electrical
PrevNext

Power required during the open circuit and short circuit test is

A

losses incurring in the transformer

B

executing the power requirements by measuring instruments

C

power for the core losses only

D

all of the mentioned

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalBasic Electrical
Option A

losses incurring in the transformer

Quick Summary:

In both open circuit and short circuit tests, the power measured by the wattmeter accounts for the total power drawn by the transformer at that specific condition. This power corresponds to the losses occurring within the transformer: core (iron) losses during the open circuit test and ohmic (copper) losses during the short circuit test.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

In both open circuit and short circuit tests, the power measured by the wattmeter accounts for the total power drawn by the transformer at that specific condition. This power corresponds to the losses occurring within the transformer: core (iron) losses during the open circuit test and ohmic (copper) losses during the short circuit test.

ЁЯФв Key Formulas

Poc=VratedтЛЕI0тЛЕcosтБб(╧Х0)P_{oc} = V_{rated} \cdot I_0 \cdot \cos(\phi_0)PocтАЛ=VratedтАЛтЛЕI0тАЛтЛЕcos(╧Х0тАЛ) тАФ Represents iron losses (hysteresis + eddy current) in the core

Psc=Irated2тЛЕReqP_{sc} = I_{rated}^2 \cdot R_{eq}PscтАЛ=Irated2тАЛтЛЕReqтАЛ тАФ Represents copper losses in the windings at rated current

тЪЩя╕П Working Principle

The Open Circuit (OC) test is performed at rated voltage to measure core losses (Pi=PocP_i = P_{oc}PiтАЛ=PocтАЛ), which are constant. The Short Circuit (SC) test is performed at rated current to measure full-load copper losses (Pcu,fl=PscP_{cu,fl} = P_{sc}Pcu,flтАЛ=PscтАЛ), which vary with the square of the current (I2RI^2RI2R). Both tests assume the power consumed by measuring instruments (voltmeter, ammeter, wattmeter) is negligible compared to the transformer losses or is accounted for via correction factors.

ЁЯУМ Key Points
  • тЦ╕

    OC test is usually performed on the Low Voltage (LV) side to keep the voltage within a measurable range.

  • тЦ╕

    SC test is performed on the High Voltage (HV) side to keep the required current within a safe, measurable limit.

  • тЦ╕

    Wattmeter readings in these tests essentially measure the active power dissipated as heat in the transformer components.

  • тЦ╕

    Instrument loss is generally considered negligible or corrected using the circuit configuration.

тЬЕ Advantages
  • тЦ╕

    Provides an efficient method to separate core and copper losses.

  • тЦ╕

    Allows for the determination of transformer efficiency without loading it to full capacity.

тЭМ Disadvantages / Limitations
  • тЦ╕

    OC test provides no information about copper losses.

  • тЦ╕

    SC test provides no information about core losses.

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Calculation of efficiency and voltage regulation of transformers.

  • тЦ╕

    Estimation of equivalent circuit parameters (R0,X0,Req,XeqR_0, X_0, R_{eq}, X_{eq}R0тАЛ,X0тАЛ,ReqтАЛ,XeqтАЛ).

ЁЯУД Additional Information
  • тЦ╕

    Option C is partially correct as the OC test measures core losses, but it is incomplete because the SC test measures copper losses.

  • тЦ╕

    Option B is incorrect because instrument power is usually minimized or corrected and does not represent the transformer losses themselves.

  • тЦ╕

    The total power measured is specifically the loss associated with the excitation (OC) or the load (SC) state of the transformer.

ЁЯУК Diagram / Illustration
Transformer Power Measurements
Pmeasured=PlossesP_{measured} = P_{losses}PmeasuredтАЛ=PlossesтАЛ
OC Test: PmeasuredтЙИPcoreP_{measured} \approx P_{core}PmeasuredтАЛтЙИPcoreтАЛ
SC Test: PmeasuredтЙИPcopperP_{measured} \approx P_{copper}PmeasuredтАЛтЙИPcopperтАЛ
Total Power = Sum of internal losses
тЬЕ

A is correct тАФ The wattmeter measures the power dissipated as losses (either iron or copper) within the transformer core and windings during these tests.

Core Concepts Used
Click any tag to open in AI Tutor
Transformer Testing Core Losses Copper Losses Wattmeter Calibration
ЁЯТб EXAM TIP

Always remember that the OC test corresponds to core losses (constant) and the SC test corresponds to copper losses (variable) in electrical machines.

Related Questions

ElectricalBasic Electrical
Batteries are charged by
ElectricalBasic Electrical
48 ampere-hour capacity would deliver a current of
ElectricalBasic Electrical
The lead-acid cell should never be discharged beyond
ElectricalBasic Electrical
In a lead-acid cell, lead is called as
ElectricalBasic Electrical
Undercharging of chemical batteries