Join 60,000+ competitive exam aspirants
The area under a flow-duration curve represents
Total units of energy available
Total power available at site
Total quantity of run-off during that period
Maximum rate of run-off during that period
Total quantity of run-off during that period
The flow-duration curve is a plot of flow magnitude versus the percentage of time that flow is equalled or exceeded. Since the x-axis represents time duration and the y-axis represents discharge (flow rate), the area under the curve is the integral of flow over time, yielding the total volume of water (run-off) passed during that specific period.
The flow-duration curve is a plot of flow magnitude versus the percentage of time that flow is equalled or exceeded. Since the x-axis represents time duration and the y-axis represents discharge (flow rate), the area under the curve is the integral of flow over time, yielding the total volume of water (run-off) passed during that specific period.
V=тИл0TтАЛQ(t)dt тАФ Total volume (run-off) calculated as the integral of flow Q over time T
Mathematically, the area A is given by A=тИлQ(t)dt, where Q is the discharge and t is time. By plotting the flow in descending order of magnitude, the curve allows for the estimation of total streamflow volume, which is essential for determining the storage requirements of a reservoir or the potential energy output of a hydroelectric site.
The x-axis of a flow-duration curve represents the percentage of time the flow is equalled or exceeded.
The curve is independent of the sequence of flows (it is a cumulative frequency distribution).
It is a critical tool for hydropower planning and water resource management.
Provides a simple visual summary of flow variability.
Useful for determining firm power and secondary power potential in hydro projects.
Does not provide information on the chronological sequence of flow events.
Cannot determine the specific timing of droughts or floods.
Hydroelectric power plant sizing.
Irrigation water requirement estimation.
Water quality management and pollution load analysis.
Option A is incorrect as energy available requires multiplying discharge by the head and conversion efficiency (P=╬╖╧БgQH).
Option B is incorrect because power depends on the hydraulic head in addition to the flow rate.
The flow-duration curve is often used to calculate the 'Firm Flow', which is the flow available for a specific high percentage of time (e.g., 90% or 95%).
C is correct тАФ The area under the flow-duration curve represents the total volume of water or total quantity of run-off passed during the period considered.
Always remember: Flow-Duration Curves deal with volume (Area = Q * t), whereas Power-Duration Curves would require multiplying by Head and efficiency.