Join 60,000+ competitive exam aspirants
The drawback of spray ponds is
Large ground area is required especially in case of large sized power plants
Loss of water due to evaporation
Considerable quantity of water is carried away in air when its velocity is high
All of above
All of above
Spray ponds are cooling systems used in power plants to lower the temperature of condenser cooling water. They suffer from inherent design limitations including large land footprints, significant water loss through evaporation, and high sensitivity to wind conditions, leading to spray drift.
Spray ponds are cooling systems used in power plants to lower the temperature of condenser cooling water. They suffer from inherent design limitations including large land footprints, significant water loss through evaporation, and high sensitivity to wind conditions, leading to spray drift.
Q=mтЛЕcpтАЛтЛЕ╬ФT тАФ Heat transfer capacity
PevapтАЛтИЭvтЛЕ(esтАЛтИТeaтАЛ) тАФ Rate of evaporation relative to wind velocity v and vapor pressure deficit
Water is pumped through a network of nozzles into the air, creating a fine spray that increases the surface area for heat exchange via evaporation and convection. The cooled water falls into a shallow basin for recirculation. Performance is heavily dependent on atmospheric humidity, wind speed, and the ambient dry-bulb temperature.
High wind velocities cause water carry-over (drift loss) outside the pond basin.
The thermal efficiency is generally lower compared to cooling towers.
Requires high pumping power relative to the heat rejection achieved.
Performance is extremely climate-dependent.
Simple construction
Low initial capital cost compared to mechanical draft towers
High space requirement
High water consumption
Drift loss due to high winds
Lower heat rejection efficiency
Small to medium scale power plants
Industrial cooling applications with sufficient space
Option A relates to the physical layout constraints of the plant.
Option B relates to the mass transfer mechanism essential for cooling but detrimental to water economy.
Option C relates to the aerodynamic interaction of the spray with ambient air, leading to environmental loss.
D is correct тАФ All listed factors (land area, evaporation loss, and spray drift) represent significant operational drawbacks of spray pond cooling systems.
In power system design, always compare cooling methods based on water availability, land cost, and environmental regulations, as these significantly impact O&M costs.