The function of a surge tank is to
Supply water at constant pressure
Relieve water hammer pressure in the penstock pipe
Produce surge in the pipe line
None above
Relieve water hammer pressure in the penstock pipe
A surge tank is a small reservoir or tank connected to the penstock of a hydroelectric power plant. It acts as a pressure-balancing device that mitigates the sudden pressure rise (water hammer) caused by rapid fluctuations in the flow velocity when the turbine load changes.
A surge tank is a small reservoir or tank connected to the penstock of a hydroelectric power plant. It acts as a pressure-balancing device that mitigates the sudden pressure rise (water hammer) caused by rapid fluctuations in the flow velocity when the turbine load changes.
hsтАЛ=gLтАЛ├ЧdtdvтАЛ тАФ where hsтАЛ is the surge head, representing the pressure head variation.
When a turbine load decreases suddenly, the governor closes the gates, causing the water velocity in the long penstock to drop rapidly. This sudden stoppage generates high-pressure waves (water hammer) that could burst the pipe. The surge tank provides an open surface where this excess water can spill or rise, thereby converting the kinetic energy of the water column into potential energy and dampening the pressure shock.
Surge tanks are installed as close to the turbine as possible to minimize the length of the penstock subject to water hammer.
They act as a buffer to stabilize the flow and supply water during sudden load increases.
The presence of a surge tank reduces the design pressure requirement (and thus thickness) of the penstock pipe.
Protects penstock from damage due to water hammer.
Improves governing stability of the turbine.
Provides quick water supply during transient load demand.
Significant civil engineering cost.
Requires careful design to prevent oscillation resonance.
High-head and medium-head hydroelectric power plants.
Pumped storage power stations.
Water hammer effect: When flow velocity v changes by ╬Фv in time ╬Фt, the pressure rise p=╧БтЛЕcтЛЕ╬Фv (where c is wave speed).
Option A is incorrect because the surge tank does not maintain a constant pressure in the steady state, it merely compensates for transients.
Option C is incorrect because the tank is used to eliminate, not produce, harmful surges.
B is correct тАФ The primary function of a surge tank is to protect the penstock from excessive pressure surges (water hammer) caused by rapid flow velocity changes during turbine load rejection.
In competitive exams, remember that surge tanks are associated with 'Hydraulic Transient Analysis', which is crucial for safety in high-head power generation systems.