The function of the economizer is to
Heat up the incoming water with exhaust steam
Heat up the pulverized fuel by exhaust gases
Heat up the incoming air by exhaust gases
Heat up the incoming water by exhaust gases
Heat up the incoming water by exhaust gases
An economizer is a heat exchange device installed in the flue gas path of a steam boiler. Its primary function is to recover waste heat from the outgoing hot flue gases to pre-heat the incoming feedwater before it enters the boiler drum.
An economizer is a heat exchange device installed in the flue gas path of a steam boiler. Its primary function is to recover waste heat from the outgoing hot flue gases to pre-heat the incoming feedwater before it enters the boiler drum.
Q=m╦ЩwтАЛcpwтАЛ(ToutтАЛтИТTinтАЛ) тАФ Heat absorbed by feedwater
╬╖improvedтАЛ=╬╖originalтАЛ+╬Ф╬╖ тАФ Efficiency gain due to heat recovery
As high-temperature exhaust gases leave the boiler, they carry significant thermal energy. The economizer utilizes a series of metallic tubes through which the feed water circulates; the hot gases pass over these tubes, heating the water via convective heat transfer. This process reduces the temperature of the exhaust gases, thereby improving the overall thermal efficiency of the power plant.
Increases the overall thermal efficiency of the boiler.
Reduces the thermal stress on boiler drums by minimizing temperature differences.
Acts as a heat exchanger between flue gas and feedwater.
Requires regular maintenance to prevent soot accumulation on the tubes.
Improved boiler efficiency (typically 3% to 5% improvement).
Reduced fuel consumption.
Lower carbon footprint due to fuel savings.
Increases the draft loss in the chimney.
Susceptible to corrosion if flue gas temperature drops below the dew point.
Added complexity and space requirements in the plant layout.
Thermal power plants
Large industrial steam boilers
Economizers are typically placed after the superheater and before the air preheater.
Option A is incorrect because steam is used for energy, not for heating feedwater in an economizer; feedwater heaters (regenerators) perform that function. Option C refers to an Air Preheater, which heats combustion air, not water.
D is correct тАФ The economizer utilizes heat from waste flue gases to increase the temperature of feedwater before it reaches the boiler, thereby saving fuel.
Always remember: Economizer = Water; Air Preheater = Air; Superheater = Steam. Distinguishing these based on the working fluid is a favorite topic in competitive exams.