The functions of inter poles are
nullify reactance voltage and improve the commutation
reduce cross magnetization effect and improve commutation
both 1 and 2
none of the above
both 1 and 2
Interpoles are auxiliary poles placed midway between the main poles in a DC machine. They serve a dual purpose: neutralizing the reactance voltage (to ensure sparkless commutation) and counteracting the cross-magnetizing effect of armature reaction.
Interpoles are auxiliary poles placed midway between the main poles in a DC machine. They serve a dual purpose: neutralizing the reactance voltage (to ensure sparkless commutation) and counteracting the cross-magnetizing effect of armature reaction.
EcтАЛ=тИТLdtdiтАЛ тАФ Reactance voltage equation
MMFipтАЛтИЭIaтАЛ тАФ Interpole MMF proportionality to armature current
The interpoles are connected in series with the armature, meaning their field strength is proportional to the armature current (IaтАЛ). By generating an MMF that opposes the armature MMF in the commutating zone, they effectively cancel the cross-magnetization. Furthermore, they provide a commutating EMF that opposes the reactance voltage (LdtdiтАЛ), which is the primary cause of sparking at the brushes during the reversal of current in the armature coils.
Interpoles are wound with few turns of heavy wire and connected in series with the armature.
Their polarity is the same as the succeeding main pole in the direction of rotation for a generator.
Their polarity is the same as the preceding main pole in the direction of rotation for a motor.
They do not affect the main field flux or the speed regulation of the machine significantly.
Elimination of sparking at brushes
Allows for higher overload capacity
Enables the machine to operate at higher speeds
Increases the physical size and cost of the machine
Requires additional manufacturing complexity in the yoke
Used in almost all modern DC machines
High-performance DC motors and generators
The reactance voltage is created due to the self-induction of the coil undergoing commutation as the current reverses direction.
Without interpoles, the armature flux distorts the main flux, shifting the magnetic neutral axis (MNA) and causing sparking at the brushes.
C is correct тАФ Interpoles effectively serve both functions to ensure optimal commutation performance in DC machines.
Remember: For generators, interpole polarity matches the next pole in rotation; for motors, it matches the previous pole. This is a common point of confusion in exams.