Join 60,000+ competitive exam aspirants
The iron loss for a transformer is 400 W. If the transformer is working at its maximum efficiency then the copper loss will be
400 W
1600 W
200 W
800 W
400 W
Maximum efficiency in a transformer occurs when the constant core losses (iron losses) are exactly equal to the variable copper losses. Since the given iron loss is 400 W, the copper loss at the point of maximum efficiency must also be 400 W.
Maximum efficiency in a transformer occurs when the constant core losses (iron losses) are exactly equal to the variable copper losses. Since the given iron loss is 400 W, the copper loss at the point of maximum efficiency must also be 400 W.
PiтАЛ=PcтАЛ тАФ The condition where constant iron losses equal variable copper losses at maximum efficiency.
╬╖maxтАЛ=V2тАЛI2тАЛcos╧Х2тАЛ+2PiтАЛV2тАЛI2тАЛcos╧Х2тАЛтАЛ тАФ Efficiency formula substituted with the condition PcтАЛ=PiтАЛ.
The efficiency of a transformer is given by ╬╖=Output+Iron┬аLoss+CopperLossOutputтАЛ. Since iron loss (PiтАЛ) is constant and copper loss (PcтАЛ) varies as the square of the load current (I2R), differentiating efficiency with respect to load current and setting it to zero proves that the maximum efficiency point is reached when PiтАЛ=PcтАЛ.
Iron loss (PiтАЛ) is independent of load and remains constant.
Copper loss (PcтАЛ) is proportional to the square of the load current (I2R).
Transformer efficiency is highest when the 'constant' and 'variable' loss components are balanced.
Maximum efficiency occurs at a specific load fraction x=Pc,fullтИТloadтАЛPiтАЛтАЛтАЛ.
Optimization of transformer sizing for specific load profiles.
Ensures minimum heat dissipation and energy wastage during operation.
Maximum efficiency point is fixed; transformer is less efficient at low or very high loads.
Actual load variations in real-world distribution systems rarely sit exactly at the maximum efficiency point.
Design of distribution transformers for base-load operations.
Performance evaluation in electrical machine testing laboratories.
At maximum efficiency, the total losses are exactly twice the iron loss value.
Option B (1600 W) is incorrect because it violates the equilibrium condition.
Option C and D are incorrect as they imply a mismatch between constant and variable losses at the optimal load point.
A is correct тАФ The transformer reaches maximum efficiency when the constant iron loss is equal to the variable copper loss.
Always remember that for any machine where a fixed loss and a variable loss exist (like DC motors or transformers), efficiency is maximized when the fixed loss equals the variable loss.