Join 60,000+ competitive exam aspirants
The leakage resistance of a 50 km long cable is 1 MΩ. For a 100 km long cable it will be
1 MΩ
2 MΩ
0.66 MΩ
None of the above
None of the above
D is correct because the leakage resistance for 100 km is 0.5 MΩ, which is not listed among the given options A, B, or C.
Length of cable L1 = 50 km, Leakage resistance R1 = 1 MΩ. Length of cable L2 = 100 km.
R=A⋅Gρ=g⋅L1
Understanding Leakage Resistance
Leakage resistance is inversely proportional to the length of the cable because the leakage current path is in parallel across the insulation length. If 'g' is the leakage conductance per unit length, then the total conductance 'G' for length 'L' is G=g×L.
G∝L
Relating Resistance and Conductance
Since resistance is the reciprocal of conductance (R=1/G), the leakage resistance 'R' is inversely proportional to the length 'L' of the cable.
R∝L1
Calculating Resistance for 100 km
Given R1=1 MΩ for L1=50 km. For L2=100 km (L2=2×L1), the new resistance R2 will be R1/2.
R2=21 MΩ=0.5 MΩ
D is correct because the leakage resistance for 100 km is 0.5 MΩ, which is not listed among the given options A, B, or C.
Always distinguish between conductor resistance (which is directly proportional to length: R=ρL/A) and insulation/leakage resistance (which is inversely proportional to length).