Join 60,000+ competitive exam aspirants
Top most conductor in HV transmission line is
R-phase conductor
Y-phase conductor
Phase conductor
Earth conductor
Earth conductor
In an overhead high-voltage (HV) transmission line, the earth conductor (also known as the ground wire or shield wire) is positioned at the highest point of the tower structure. It serves as a protective shield against direct lightning strikes by providing a low-impedance path to the ground.
In an overhead high-voltage (HV) transmission line, the earth conductor (also known as the ground wire or shield wire) is positioned at the highest point of the tower structure. It serves as a protective shield against direct lightning strikes by providing a low-impedance path to the ground.
ZsurgeтАЛ=CLтАЛтАЛ тАФ Surge impedance of the transmission line
EinducedтАЛ=MdtdiтАЛ тАФ Induced voltage due to lightning stroke
The earth conductor is grounded at every transmission tower. It functions as a Faraday cage protector for the phase conductors below it. When a lightning stroke approaches, the grounded wire intercepts the strike, keeping the discharge away from the energized phase conductors, thereby preventing insulator flashovers and system outages.
The earth conductor is typically made of galvanized steel or ACSR (Aluminum Conductor Steel Reinforced).
It does not carry load current under normal operating conditions.
The placement is determined by the shielding angle (usually 20┬░ to 30┬░) to ensure total coverage of phase conductors.
It helps in reducing the zero-sequence impedance of the line.
Protects phase conductors from direct lightning strikes.
Provides a return path for fault current during line-to-ground faults.
Reduces the risk of insulator string damage.
Adds weight to the transmission tower structure.
Increases the total cost of line construction.
Requires proper maintenance to prevent corrosion at the tower clamp connection.
All EHV and UHV transmission lines.
Substation lightning protection.
Distribution lines in high lightning-prone areas.
The earth conductor is connected to the top of the tower, which is connected to the ground rod at the footing.
Options A, B, and C refer to current-carrying phase conductors which are always kept below the earth wire to maintain phase-to-ground clearance.
D is correct тАФ The earth conductor is placed at the topmost position to shield the energized conductors from lightning strokes.
In exams, remember that the shield wire's location is critical for the 'Shielding Angle' calculation; a smaller shielding angle provides better protection.