Join 60,000+ competitive exam aspirants
Use of additional shunt capacitor can be made for increasing the capability of line as it
Reduces surge impedance
Increases phase shift
Increases load angle
All of above
Reduces surge impedance
Shunt compensation in electrical transmission lines is primarily used to adjust the surge impedance of the line. By adding a shunt capacitor, the characteristic impedance (ZcтАЛ) of the line is modified, which facilitates a higher power transfer capability, especially in long transmission lines.
Shunt compensation in electrical transmission lines is primarily used to adjust the surge impedance of the line. By adding a shunt capacitor, the characteristic impedance (ZcтАЛ) of the line is modified, which facilitates a higher power transfer capability, especially in long transmission lines.
ZcтАЛ=CLтАЛтАЛ тАФ Surge impedance of a lossless transmission line
PSILтАЛ=ZcтАЛV2тАЛ тАФ Surge Impedance Loading (SIL)
The surge impedance of a transmission line is given by ZcтАЛ=CLтАЛтАЛ. By placing a shunt capacitor in parallel, the total shunt capacitance (C) of the line effectively increases. Since C is in the denominator of the ZcтАЛ formula, an increase in C results in a decrease in the surge impedance (ZcтАЛ). This shift allows the system to operate closer to its Surge Impedance Loading (SIL), defined as PSILтАЛ=ZcтАЛV2тАЛ, thereby increasing the maximum power transfer capability.
Shunt capacitors increase the total shunt capacitance of the transmission line.
Higher capacitance reduces the Surge Impedance (ZcтАЛ).
Reduction in ZcтАЛ leads to an increase in the SIL, allowing more power to be transmitted over the same line.
Shunt compensation is essential for maintaining voltage stability at the receiving end of long lines.
Improved voltage profile along the line
Increased power transfer capability
Reduction in line losses for a given power transfer
Risk of overvoltage during light load conditions
Need for complex switching control mechanisms
Long-distance EHV transmission lines
Voltage regulation in radial distribution networks
SIL represents the power delivered by a line to a purely resistive load equal to the surge impedance.
Option B and C are incorrect because increasing phase shift or load angle is generally associated with series compensation or different control strategies, not the primary mechanism of shunt capacitors for increasing capability.
A is correct тАФ The use of a shunt capacitor increases the effective shunt capacitance of the line, which decreases the surge impedance (ZcтАЛ), thereby increasing the Surge Impedance Loading (SIL) and total power capability.
Always remember that shunt compensation affects the shunt parameters (C) while series compensation affects the series parameters (L) of the transmission line model.