What is the coefficient of coupling for a transformer in which 10% of the total flux generated in the primary does not pass through the secondary?
90
90
The coefficient of coupling (k) represents the fraction of the total primary flux that links the secondary winding. Given that 10% of the flux is leakage flux, the useful flux linking the secondary is 90% (or 0.9) of the total flux.
The coefficient of coupling (k) represents the fraction of the total primary flux that links the secondary winding. Given that 10% of the flux is leakage flux, the useful flux linking the secondary is 90% (or 0.9) of the total flux.
k=╬жpтАЛ╬жmтАЛтАЛ тАФ Definition of coupling coefficient
╬жmтАЛ=╬жpтАЛтИТ╬жleakтАЛ тАФ Relationship between fluxes
The coefficient of coupling is defined as the ratio of mutual flux (╬жmтАЛ) to the total flux generated by the primary winding (╬жpтАЛ). Since ╬жmтАЛ=╬жpтАЛтИТ╬жleakтАЛ, and leakage is 0.10 ╬жpтАЛ, then ╬жmтАЛ=0.90╬жpтАЛ. Thus, k=╬жpтАЛ╬жmтАЛтАЛ=0.9.
The value of k ranges from 0 to 1.
For an ideal transformer, k=1 (zero leakage flux).
For air-core transformers, k is typically very low.
For iron-core transformers, k is very close to 1.
High coupling improves voltage regulation.
Reduces leakage reactance drops.
High coupling in air-core is difficult to achieve.
High coupling does not account for eddy current losses.
Power transformers
Inductive coupling circuits
The coupling coefficient k=k1тАЛk2тАЛтАЛ, where k1тАЛ and k2тАЛ are the coupling factors for primary and secondary windings respectively.
Option B (90) represents the percentage (90%), whereas k is technically 0.9.
B is correct тАФ Since 10% of the flux is leakage, 90% of the flux links the secondary, resulting in a coefficient of coupling of 0.9 or 90%.
Remember that k is a dimensionless ratio. If a question asks for a percentage, always convert the decimal coefficient to percentage by multiplying by 100.