Join 60,000+ competitive exam aspirants
Which parameter does not change during transformation action in a transformer?
Voltage
Frequency
Current
None of these
Frequency
A transformer operates on the principle of electromagnetic induction, which relies on a time-varying magnetic flux to induce an electromotive force (EMF). Because the input supply frequency determines the rate of change of the flux in the core, the frequency must remain constant for the transformer to maintain its intended flux linkage and voltage transformation ratio.
A transformer operates on the principle of electromagnetic induction, which relies on a time-varying magnetic flux to induce an electromotive force (EMF). Because the input supply frequency determines the rate of change of the flux in the core, the frequency must remain constant for the transformer to maintain its intended flux linkage and voltage transformation ratio.
E=4.44fN╬жmтАЛ тАФ Transformer EMF equation showing dependence on frequency (f)
f1тАЛ=f2тАЛ тАФ Frequency invariance principle
When an AC voltage is applied to the primary winding, it produces a time-varying magnetic flux in the core. According to Faraday's Law, e=тИТNdtd╬жтАЛ, the induced voltage is proportional to the rate of change of flux. Since ╬ж=╬жmтАЛsin(╧Йt), the derivative involves the angular frequency ╧Й=2╧Аf. If frequency changed, the induced EMF and the core saturation characteristics would change, violating the fundamental operation of the transformer.
The transformer is a constant frequency device.
Changing frequency would alter the core flux density and potentially lead to saturation (BmтАЛтИЭfVтАЛ).
Transformer impedance varies with frequency (XLтАЛ=2╧АfL), so operation at wrong frequencies leads to incorrect performance.
Enables efficient long-distance AC power transmission.
Allows voltage levels to be matched to load requirements.
Cannot transform DC signals because the rate of change of flux is zero.
Size is inversely proportional to frequency (lower frequency requires larger cores).
Power grid voltage step-up/step-down.
Impedance matching in electronic circuits.
In India, the standard power frequency is 50 Hz.
Option A (Voltage) changes as per the turns ratio (Step-up or Step-down).
Option C (Current) changes inversely to voltage to maintain constant power (neglecting losses).
B is correct тАФ Frequency is the fundamental parameter that remains unchanged during the transformation process in a transformer.
Always remember that transformers change voltage and current levels by conservation of power, but they can only operate effectively at the frequency for which the core material is designed.