Join 60,000+ competitive exam aspirants
Which among these is a type of surge arrestor?
Conventional gapped arrestors
Metal oxide arrestors
Conventional gapped arrestors and Metal oxide arrestors
None of these
Conventional gapped arrestors and Metal oxide arrestors
Surge arrestors are protective devices used in power systems to protect equipment from transient overvoltages caused by lightning or switching surges. They act as non-linear resistors that divert high-energy surges to the ground, maintaining system insulation integrity.
Surge arrestors are protective devices used in power systems to protect equipment from transient overvoltages caused by lightning or switching surges. They act as non-linear resistors that divert high-energy surges to the ground, maintaining system insulation integrity.
I=kV╬▒ тАФ Non-linear current-voltage relationship where ╬▒ is the exponent (high for ZnO materials).
The principle relies on the V-I characteristics of the material. Conventional gapped arrestors use a series spark gap to disconnect the system under normal voltage and a valve element to limit follow-through current. Metal oxide arrestors (MOA) utilize non-linear zinc-oxide (ZnO) blocks that exhibit extremely high resistance at operating voltage and low resistance during surges, eliminating the need for series gaps.
Surge arrestors are connected in parallel with the equipment to be protected.
The primary requirement of an arrestor is to have a low discharge voltage and high energy absorption capability.
Metal oxide arrestors are currently the industry standard due to their fast response time and gapless design.
Protects insulation from dielectric breakdown
Prevents equipment damage from transient overvoltages
Aging of non-linear resistors can occur over time
Requires proper selection based on MCOV (Maximum Continuous Operating Voltage)
Substation transformers
High-voltage transmission lines
Distribution networks
| Feature | Conventional | Metal Oxide |
|---|---|---|
Series Gap | Present | Absent |
Response Speed | Slower | Extremely Fast |
ZnO arrestors are often referred to as 'Gapless' arrestors.
Option D is incorrect because both types listed are standard industry classifications for surge protection.
C is correct тАФ Both conventional gapped arrestors and metal oxide arrestors are recognized types of surge protection devices used in power systems.
Always remember that surge arrestors are connected in parallel (shunt), whereas fuses or relays often monitor in series, to ensure surge currents bypass the protected equipment safely.