Which of the following are variable losses?
eddy current loss
hysteresis loss
shunt field copper loss
armature copper loss
armature copper loss
Variable losses in a DC machine are those that change in proportion to the square of the load current (Ia2тАЛ). Since armature current varies according to the load applied to the machine, the Ia2тАЛRaтАЛ loss is classified as a variable loss.
Variable losses in a DC machine are those that change in proportion to the square of the load current (Ia2тАЛ). Since armature current varies according to the load applied to the machine, the Ia2тАЛRaтАЛ loss is classified as a variable loss.
PvarтАЛ=Ia2тАЛRaтАЛ тАФ Formula for Armature Copper Loss
PtotalтАЛ=PconstantтАЛ+PvariableтАЛ тАФ Total Loss Equation
The total power loss in a DC machine is the sum of constant and variable losses. Constant losses include iron losses (hysteresis and eddy current) and mechanical losses (friction and windage), which remain relatively steady regardless of load. Variable losses are dominated by copper losses in the windings that carry the load current; specifically, the armature resistance RaтАЛ dissipates energy as PvarтАЛ=Ia2тАЛRaтАЛ, which increases quadratically with the load current.
Constant losses (Iron + Mechanical) do not depend on load current.
Variable losses depend on the square of the armature current.
Maximum efficiency occurs when constant losses equal variable losses.
Shunt field copper loss is considered constant in a shunt machine if the terminal voltage is constant.
Predictability of loss behavior under varying load
Essential for calculating the point of maximum efficiency
Increases heat generation significantly at high loads
Reduces overall machine efficiency during peak demand
DC Motor efficiency testing
Performance analysis for variable speed drives
Hysteresis and eddy current losses are categorized as constant losses.
Shunt field copper loss is V2/RshтАЛ, which is constant for a shunt machine connected to a constant voltage source.
Series field copper loss is also a variable loss (Is2тАЛRsтАЛ).
D is correct тАФ Armature copper loss varies directly with the square of the armature current, making it the primary component of variable losses in DC machines.
Always remember the condition for maximum efficiency: Constant Losses = Variable Losses (Fixed┬аLoss=Ia2тАЛRaтАЛ).