Which of the following DC Motor requires 3 point starter?
Shunt motor
Series motor
Shunt motor as well as compound motors
Shunt, compound and series motor
Shunt motor as well as compound motors
A 3-point starter is required for DC Shunt and Compound motors to limit the high starting current and protect the armature. Since these motors have a low armature resistance (RaтАЛ), they would draw excessive current upon start-up in the absence of a back EMF (EbтАЛ), potentially damaging the windings.
A 3-point starter is required for DC Shunt and Compound motors to limit the high starting current and protect the armature. Since these motors have a low armature resistance (RaтАЛ), they would draw excessive current upon start-up in the absence of a back EMF (EbтАЛ), potentially damaging the windings.
IaтАЛ=RaтАЛ+RextтАЛVтИТEbтАЛтАЛ тАФ Armature current during starting
EbтАЛ=60AP╧ХZNтАЛ тАФ Back EMF equation
At standstill, the back EMF (EbтАЛ) is zero. The starter introduces an external starting resistance in series with the armature to maintain IaтАЛ=RaтАЛ+RextтАЛVтИТEbтАЛтАЛ. As the motor gains speed, EbтАЛ increases, and the external resistance is gradually cut out. The 3-point starter specifically includes three terminals: Line (L), Armature (A), and Field (F).
The 3-point starter uses an NVC (No-Volt Coil) in series with the field circuit for protection.
DC Series motors are not used with 3-point starters because a break in the field circuit (if field current drops) would cause dangerous overspeeding.
A 4-point starter is preferred when the shunt field current must be varied over a wide range.
Prevents heavy initial inrush current
Protects armature windings from burning
Provides protection against field failure
Not suitable for wide speed variation if field current is weak
Mechanical parts like contact studs are prone to wear
Industrial DC shunt motor drives
Constant speed DC compound motor applications
Option B (Series motor) requires a 2-point starter because the field and armature are in series; if the field opens, the motor stops safely, whereas in shunt motors, opening the field causes runaway.
The 3rd point in the 3-point starter connects to the field circuit.
C is correct тАФ Both DC shunt and compound motors utilize a 3-point starter to restrict the high starting current generated due to low armature resistance at zero speed.
Always remember: 2-point for Series, 3-point for Shunt/Compound, and 4-point for Shunt/Compound with wide speed regulation.