Examoogle
ExamsTest SeriesCBATRank CheckPrevious Year PapersPassBook StoreMy BooksAI Tutor
ЁЯЫТ0
рдЕA
Examoogle

India's most trusted platform for competitive exam PDF books. Expert-authored, watermark-protected, instant access.

Exams & Practice
All Exams & SyllabusMock Test SeriesPrevious Year PapersPractice Questions (MCQs)Recruitment Notifications
Quick Links
Examoogle AI TutorExam NewsBook StoreMy BooksLogin / Sign Up
Support
About UsRefund PolicyPrivacy PolicyTerms of UseContact Us
┬й 2026 Examoogle. India's #1 competitive exam AI tutor.
ЁЯФТ SSL SecuredЁЯУ▒ UPI AcceptedЁЯз╛ GST Invoice
Examoogle

Join 60,000+ competitive exam aspirants

or with email
By continuing, you agree to ourTerms of Service&Privacy Policy
Your Cart
SubtotalтВ╣0
TotalтВ╣0
Examoogle тАв User тАв info@examoogle.com тАв EE-2024-8821
Chapter 1 of 12 тАв Page 1 of 248ЁЯФТ Protected PDF тАв Watermarked
Back to Practice Questions
ElectricalPower System
PrevNext

Which of the following equipment is used to limit short circuit current level in a substation?

A

Isolator

B

Lightning arrester

C

Coupling capacitor

D

Series reactor

Correct Answer

тЪЩя╕П TE тАв Technical Concept & PrincipleElectricalPower System
Option D

Series reactor

Quick Summary:

A series reactor is an inductor connected in series with a power line to limit the magnitude of fault currents during a short circuit condition. By adding inductive reactance to the system, it increases the total impedance of the circuit, thereby reducing the fault current IscI_{sc}IscтАЛ to a level that equipment like circuit breakers can safely interrupt.

тЪЩя╕ПTETechnical SolutionConcept & Principle
ЁЯТб Explanation

A series reactor is an inductor connected in series with a power line to limit the magnitude of fault currents during a short circuit condition. By adding inductive reactance to the system, it increases the total impedance of the circuit, thereby reducing the fault current IscI_{sc}IscтАЛ to a level that equipment like circuit breakers can safely interrupt.

ЁЯФв Key Formulas

Isc=VZeqI_{sc} = \frac{V}{Z_{eq}}IscтАЛ=ZeqтАЛVтАЛ тАФ General fault current calculation

XL=2╧АfLX_L = 2\pi f LXLтАЛ=2╧АfL тАФ Inductive reactance of the reactor

тЪЩя╕П Working Principle

When a short circuit occurs, the fault current is primarily limited by the source impedance. By inserting a series reactor with reactance XL=2╧АfLX_L = 2\pi f LXLтАЛ=2╧АfL, the total impedance of the fault loop is increased to Ztotal=(R+RL)2+(X+XL)2Z_{total} = \sqrt{(R+R_{L})^2 + (X+X_{L})^2}ZtotalтАЛ=(R+RLтАЛ)2+(X+XLтАЛ)2тАЛ. This significantly reduces the peak short-circuit current, protecting downstream switchgear from excessive thermal and mechanical stresses.

ЁЯУМ Key Points
  • тЦ╕

    Series reactors are essentially large air-core or iron-core inductors.

  • тЦ╕

    They act as current-limiting devices without significantly affecting normal operating conditions.

  • тЦ╕

    They help in reducing the kVA rating requirements for circuit breakers.

  • тЦ╕

    The primary disadvantage is the continuous voltage drop across the reactor during normal operation.

тЬЕ Advantages
  • тЦ╕

    Protects circuit breakers from exceeding their MVA breaking capacity.

  • тЦ╕

    Reduces mechanical stress on busbars and insulators during a fault.

  • тЦ╕

    Simple construction and low maintenance.

тЭМ Disadvantages / Limitations
  • тЦ╕

    Causes a constant voltage drop in the system.

  • тЦ╕

    Creates an additional power loss (I2RI^2RI2R).

  • тЦ╕

    Degrades voltage regulation under heavy load conditions.

ЁЯЫая╕П Applications / Uses
  • тЦ╕

    Substation busbar protection.

  • тЦ╕

    Feeder protection in high-voltage networks.

  • тЦ╕

    Limiting fault levels in interconnected power grids.

ЁЯУД Additional Information
  • тЦ╕

    Lightning arresters (Option B) are used for overvoltage protection from surges, not for limiting short-circuit current.

  • тЦ╕

    Isolators are mechanical switches meant to disconnect circuits during no-load conditions.

  • тЦ╕

    Coupling capacitors are primarily used for power line carrier communication (PLCC).

ЁЯУК Diagram / Illustration
Short Circuit Current Reduction FormulaI_sc тЙИ (V_phase / X_(system) +X_reactor}Where X_reactor is the series inductive reactance
тЬЕ

D is correct тАФ A series reactor increases the total circuit impedance during a fault, thereby limiting the maximum prospective short-circuit current.

Core Concepts Used
Click any tag to open in AI Tutor
Fault current limiting Power system protection Inductive reactance
ЁЯТб EXAM TIP

Always remember: Series reactors for current limiting, Shunt reactors for voltage control (compensation of capacitive effect in long lines).

Related Questions

ElectricalPower System
The specified quantities of Generation bus is
ElectricalPower System
When an alternator connected to the bus-bar is shut down the bus-bar voltage will
ElectricalPower System
The current drawn by the line due to corona losses is _______
ElectricalPower System
The specified quantities of load bus are
ElectricalPower System
The advantages of high transmission voltage are ______